Permit: T06CM03260

Parcel: 107092230


Addresses:

455 W KELSO ST #240

Inspection Status: Denied

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
09/20/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. INSTALL ANTI-TIP DEVICE ON RANGE (SEE RANGE INSTRUCTIONS)
2. PROVIDE CONNECTOR FOR DISHWASHER CORD
3. PROVIDE CONNECTOR FOR HOOD WIRING
4. PROVIDE GFI PROTECTION FOR KITCHEN COUNTER RECEPTACLES.
5. GROUND ALL SWITCHES WITH EQUIPMENT GROUND AS REQUIRED.
6. PANEL DIRECTORY IS NOT CORRECTLY IDENTIFIED.
7. HALL SMOKE DETECTOR NOT INSTALLED PER MANUFACTURER INSTRUCTIONS.
8. PROVIDE DISCONNECTING MEANS FOR WATER HEATER.
9. BEDROOM LIGHT NOT WORKING
10. SEAL HOLE IN TOP OF SUB-PANEL

ALL WORK TO BE DONE BY LICENSED ELECTRICAL CONTRACTOR.