Permit: T06CM03080
Permit Details
Apply Date:
05/23/2006
Applicant:
JACA DESIGN
Description:
GENERAL REPAIRS, ELEC RECONNECT
Contractors:
- POOR BOYS GENERAL REMODELING INC
Permit Reviews
Permit Number - T06CM03080
Permit Status: Final
Permit Description: GENERAL REPAIRS, ELEC RECONNECT
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
05/23/2006 | OTHER | 05/23/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM03080
Permit Status: Final
Permit Description: GENERAL REPAIRS, ELEC RECONNECT
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
05/23/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T06CM03080
Permit Description: GENERAL REPAIRS, ELEC RECONNECT
Total Completed Inspections - 8
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/31/2006 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* |
10/10/2006 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | IVRS - Inspection :* CHECK SMOKE DETECTOR PLACEMENT AND TIGHTEN GROUND SCREWS ON METAL BOXES. |
12/18/2006 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* PLUMBING FINAL OK OK FOR C OF O S.T.O.I |
12/20/2006 | TEP CLEARANCE - AM | BFLORES | Approved | RECN PER D.SANTA CRUZ |
12/21/2006 | ELECTRIC - RECONNECT | RMAJUTA | Approved | IVRS - Inspection : See detailed listing on site.| 999* NO POWER YET |
12/29/2006 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245$ 1) PANEL DIRECTORY NOT PROPERLY INDENTIFIED-MAKE SURE IT IS CLEAR, LEGIABLE AND GOES TO WHAT IT SAYS-NEC 408.4 2) BEDROOM WIRING OUTLETS INCLUDING SMOKE DETECTORS NEED ARC FAULT PROTECTION-NEC 210.12 3) GROUND ALL SWITCHES-NEC 404.9 B 4) WATER HEATER MINIMUM SIZE GROUND TO BE #10 CU-NEC 250.122 5) PROVIDE DISCONNECTING MEANS FOR WATER HEATER NEC 422.31 B 6) INSTALL LIGHT BULBS (PROPERLY SIZED) IN ALL FIXTURES AND HOOD 7) PROVIDE CONNECTOR FOR DISHWASHER CORD-NEC 400.14 8) PROVIDE GFI PROTECTION FOR BATHROOM RECEPTACLE-NEC 210.8 9) SHEET METAL SCREWS NOT ALLOWED FOR PANEL GROUND BAR-NEC 250.8 10) SEPERATE NEUTRALS AND GROUNDS IN PANEL-NEC 250.24 A 5 11) MULTI WIRE BRANCH CKT PHASE CONDUCTORS TO TERMINATE ON SEPERATE PHASES IN PANEL-NEC 100 12) NEED LIGHT OR SWITCHED RECEPTACLE IN LIVING ROOM-NEC 210.70 13) AT ROOF TOP UNIT: IDENTIFY DISCONNECT, PROPERLY SECURE/MOUNT/SUPPORT DISCONNECT, INSTALL PROPER FUSES IN DISCONNECT AND EQUIPMENT GROUND TO UNIT UNDERSIZED 14) ALL WORK TO BE DONE BY LICENSED ELECTRICAL CONTRACTOR, WILL PAY FEE IF NOT CORRECT NEXT INSPECTION. HAVE CONTRACTOR CALL ME ASAP OR A STOP WORK ORDER MAY BE ISSUED |
07/06/2007 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
07/09/2007 | PERMIT FINALED | BFLORES | Approved |