Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T06CM02289
Permit Details
Apply Date:
04/20/2006
Applicant:
D R HORTON HOMES *C
Description:
SFR TD # 16-63-57
Contractors:
- D R HORTON HOMES *C
Permit Reviews
Permit Number - T06CM02289
Permit Status: C of o
Permit Description: SFR TD # 16-63-57
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/20/2006 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 04/25/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM02289
Permit Status: C of o
Permit Description: SFR TD # 16-63-57
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
04/20/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM02289
Permit Description: SFR TD # 16-63-57
Total Completed Inspections - 24
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/30/2006 | PLUMBING - SEWER HCS CONNECT | RFREIDIN | Approved | IVRS - Inspection :* |
08/30/2006 | PLUMBING - ROUGH, SOIL | RFREIDIN | Approved | IVRS - Inspection :* |
09/12/2006 | ELECTRIC - UNDERGROUND | WNORTH | Approved | IVRS - Inspection :* |
09/12/2006 | ELECTRIC - UFER | WNORTH | Approved | IVRS - Inspection :* |
09/12/2006 | BUILDING PRE-SLAB | WNORTH | Approved | IVRS - Inspection :* |
09/12/2006 | STEM WALL/RETAINING WALL | WNORTH | Approved | IVRS - Inspection :* |
09/12/2006 | EXCAVATION/LAYOUT REBAR & ZON | WNORTH | Approved | IVRS - Inspection :* |
11/15/2006 | ROOF NAILING | WNORTH | Approved | IVRS - Inspection :* |
11/15/2006 | EXT METAL CLIPS/EXT SHEATHING | WNORTH | Approved | IVRS - Inspection :* |
12/06/2006 | ELECTRIC - TEMPORARY SERVICE | CRUIZ | Approved | IVRS - Inspection :* |
12/06/2006 | ELECTRIC - CABLE DROP | CRUIZ | Approved | IVRS - Inspection :* |
12/07/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED PER C. RUIZ |
12/18/2006 | FRAMING | CRUIZ | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) BLK AT COMBUSTION AIR VENTS 2) SHIM LETINS ALL WALLS 3) MISSING H.D. AT STAIRWAY SHEARWALL 4) LOAD WINDOW NOT INSTALLED 5) DOWNSTAIRS BATH-NEED PROTECTION ON DRAIN AT CEILING FROM 2ND FLOOR 6) GAS LINE TO STOVE NEEDS TO BE SECURED IN WALL 7) NO PRESSURE READING ON GAUGE 8) A/C VENT TO MASTER BATH HAS RESTRICTION 9) BLOCK MECHANICAL BOOT IN BEDROOM AND LOFT 10) PEX LINE OVER KITCHEN SINK, NEEDS TO BE MOVED AWAY FROM CAN LIGHT 11) NO WATER PRESSURE 12) NO DWV TEST |
12/18/2006 | STUCCO MESH | CRUIZ | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/18/2006 | PLUMBING - GAS PRESSURE TEST | CRUIZ | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/18/2006 | MECHANICAL - INTERMEDIATE | CRUIZ | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/18/2006 | PLUMBING - INTERMEDIATE | CRUIZ | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/18/2006 | ELECTRIC - INTERMEDIATE | CRUIZ | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
03/26/2007 | SHEET ROCK NAILING | CRUIZ | Approved | |
03/26/2007 | MECHANICAL - FINAL | CRUIZ | Approved | IVRS - Inspection :* |
03/26/2007 | PLUMBING - FINAL | CRUIZ | Approved | IVRS - Inspection :* |
03/26/2007 | ELECTRIC - FINAL | CRUIZ | Approved | IVRS - Inspection :* |
03/26/2007 | BUILDING - FINAL | CRUIZ | Approved | IVRS - Inspection :* |
04/02/2007 | PERMIT FINALED | JWEATHER | Approved |