Permit: T06CM02026
Permit Details
Apply Date:
04/07/2006
Applicant:
RUGEN CONSTRUCTION L L C
Description:
DUPLEX:TD#16-41-59 rev 1: mirror image duplex on site plan R2 - Elec change riser R3 - Elec calcs for 100 AMP panel R4- REMOVE PORCH
Contractors:
- RUGEN CONSTRUCTION L L C
Permit Reviews
Permit Number - T06CM02026
Permit Status: Final
Permit Description: DUPLEX:TD#16-41-59
rev 1: mirror image duplex on site plan
R2 - Elec change riser
R3 - Elec calcs for 100 AMP panel
R4- REMOVE PORCH
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/05/2007 | REVISION - - 3RD | 03/06/2007 | COMPLETED |
| 03/06/2007 | REVISION - - 4TH | 03/06/2007 | COMPLETED |
| 04/07/2006 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 04/07/2006 | COMPLETED |
| 06/12/2006 | REVISION - - 1ST | 06/12/2006 | COMPLETED |
| 12/22/2006 | REVISION - - 2ND | 12/22/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM02026
Permit Status: Final
Permit Description: DUPLEX:TD#16-41-59
rev 1: mirror image duplex on site plan
R2 - Elec change riser
R3 - Elec calcs for 100 AMP panel
R4- REMOVE PORCH
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/07/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T06CM02026
Permit Description: DUPLEX:TD#16-41-59
rev 1: mirror image duplex on site plan
R2 - Elec change riser
R3 - Elec calcs for 100 AMP panel
R4- REMOVE PORCH
Total Completed Inspections - 22
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/14/2006 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* 1. PLAN APPROVAL 2. OK TO BACKFILL |
| 06/15/2006 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection :* EXCLUDES PATIOS |
| 06/15/2006 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/29/2006 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/29/2006 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/21/2006 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/21/2006 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/24/2006 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :* |
| 08/01/2006 | PLUMBING - INTERMEDIATE | RLEDONNE | Approved | IVRS - Inspection :* |
| 08/16/2006 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 09/12/2006 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/27/2006 | ELECTRIC - CABLE DROP | RMAJUTA | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. UFER WAS NOT INSPECTED 2. EACH APT DRAWS 107 AMPS AND PNL SHOW IS 200 AMPS ON PLAN 3. SERVICE MAINS WERE TO BE LARGER THAN 100 A 4. SERVICE NOT ADDRESSED 5. CALL OFFICE 791-5550 AND ASK FOR STEVE LONG TELL HIM YOU NEED TO APPLY FOR AN OVERHEAD WAIVER. |
| 01/18/2007 | ELECTRIC - TEMPORARY SERVICE | RMAJUTA | Approved | IVRS - Inspection :* |
| 01/19/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | TEC CLEARED FOR #1 & #2 PER R. MAJUTA |
| 01/26/2007 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :* CORRECTIONS MADE OK OK TO COVER |
| 01/26/2007 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :* |
| 03/07/2007 | BUILDING - FINAL | AALEGRIA | Approved | IVRS - Inspection :* |
| 03/07/2007 | MECHANICAL - FINAL | AALEGRIA | Approved | IVRS - Inspection :* |
| 10/20/2010 | PLUMBING - FINAL | LHANLY | Approved | finaled by aalegria during building inspection 3-7-7 |
| 10/20/2010 | ELECTRIC - FINAL | LHANLY | Approved | finaled by aalegria during building inspection 3-7-7 |
| 10/20/2010 | ELECTRIC - INTERMEDIATE | LHANLY | Approved | |
| 10/20/2010 | ELECTRIC - UFER | LHANLY | Approved | finaled by aalegria during building inspection 3-7-7 |