Permit Details

Status:
Closed
Type:
SINGLE FAMILY OTHER
Address NEW:
1925 E GREENLEE RD
Apply Date:
04/05/2006
Applicant:
KIVA TECHNICAL SERVICES INC ,*C
Description:
ADD NEW AC UNIT
Contractors:
  • KIVA TECHNICAL SERVICES INC ,*C

Permit Reviews

Permit Number - T06CM01936
Permit Status: Closed
Permit Description: ADD NEW AC UNIT
Start Date Submittal Complete Date Status  
04/05/2006 OTHER 04/07/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM01936
Permit Status: Closed
Permit Description: ADD NEW AC UNIT
Total Outstanding Activity Conditions - 1
Date Name
04/05/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Closed
Permit Number: T06CM01936
Permite Description: ADD NEW AC UNIT
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
04/10/2006 ELECTRIC - INTERMEDIATE N/A Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
04/10/2006 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. ALL WORK IN HOUSE NEEDS PROPER PERMITS AND INSPECTIONS.
2. ALL WORK NEEDS TO BE DONE BY A LICENSED CONTRACTOR, I.E PLUMBING, MECHANICAL, ELECTRICAL, ETC.
3. NO WORK WILL BE APPROVED, AND POWER WILL NOT BE APPROVED UNTIL THESE CORRECTIONS ARE MADE.
04/10/2006 MECHANICAL - FINAL N/A Partial Approval IVRS - Inspection :*
1. #8 WIRE ACCEPTABLE FOR 50 AMP. MAX.
2. BLOCK/CLAMP, SECURE FLEX HI OOLAGE & CONTROL WIRING CIRC.
3. DOES THIS FAN COIL HAVE 10 KW AUX.
HT. STRIP?
MARK DATA PLATE TO VERIFY ACTUAL SIZE.
THIS NEEDS #6 WIRE, SWITCH INTO FAN COIL.
4. PROVIDE TRAP AT COND. COIL DISCHARGE AHEAD OF PUMP.

Completed Inspections

Permit Status: Closed
Permit Number: T06CM01936
Permit Description: ADD NEW AC UNIT
Total Completed Inspections - 1
Date Description Inspector Results Comments
04/10/2006 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection :*