Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Final
Type:
DUPLEX NEW
Address NEW:
1719 N HUACHUCA AV 03
Apply Date:
02/22/2006
Applicant:
NORMAN AMY
Description:
NEW DUPLEX
Contractors:
  • LE COCQ CONSTRUCTION COMPANY INC

Permit Reviews

Permit Number - T06CM01065
Permit Status: Final
Permit Description: NEW DUPLEX
Start Date Submittal Complete Date Status  
01/10/2007 RESUBMITTAL 01/12/2007 COMPLETED Review Details
01/25/2008 3RD PARTY REVIEW-REVISION/OTHER 01/25/2008 COMPLETED Review Details
02/22/2006 PLANS OK TO SUBMIT - RES 3RD PARTY 02/22/2006 COMPLETED Review Details
02/22/2006 3RD PARTY REVIEW-RESIDENTIAL 05/09/2006 COMPLETED Review Details
05/09/2006 POST 3RD PARTY REVIEW 05/30/2006 COMPLETED Review Details
05/30/2006 RESUBMITTAL 06/05/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM01065
Permit Status: Final
Permit Description: NEW DUPLEX
Total Outstanding Activity Conditions - 1
Date Name
02/22/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T06CM01065
Permit Description: NEW DUPLEX
Total Completed Inspections - 35
Date Description Inspector Results Comments
05/09/2007 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*
1. ABS DWV UNDERGROUND OK TO COVER
2. WATER TEST, ONE RISER TO TEN FEET
3. CONTRACTOR TO USE CLEAN FILL AROUND PIPE
05/11/2007 ELECTRIC - UFER RMAJUTA Approved IVRS - Inspection :*
1) #2 COPPER TO REBAR
05/11/2007 BUILDING PRE-SLAB AQUIROZ Approved IVRS - Inspection :*
05/11/2007 EXCAVATION/LAYOUT REBAR & ZON AQUIROZ Approved IVRS - Inspection :*
05/14/2007 PLUMBING - PRE SLAB RMYERS Approved IVRS - Inspection :*
1) OK FOR CONCRETE
06/18/2007 EXT METAL CLIPS/EXT SHEATHING AQUIROZ Approved IVRS - Inspection :*
06/18/2007 ROOF NAILING AQUIROZ Approved IVRS - Inspection :*
07/11/2007 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
OK TO COVER ALL AREAS
GAS PRESSURE TEST OK
07/11/2007 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection :*
07/11/2007 FRAMING AQUIROZ Approved IVRS - Inspection :*
07/16/2007 ELECTRIC - INTERMEDIATE RMAJUTA Approved IVRS - Inspection :*
07/26/2007 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
DO NOT USE FLEX ON KITCHEN EXHAUST
OK TO INSTALL VENT PIPE AFTER CABINETS ARE IN
OK FOR SHEETROCK
08/22/2007 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
08/31/2007 STUCCO MESH DWALKER Approved IVRS - Inspection :*
04/01/2008 ELECTRIC - CONSTRUCTION POWER CCLEMENS Approved IVRS - Inspection :*
04/01/2008 ELECTRIC - ABOVE CEILING CCLEMENS Approved IVRS - Inspection :*
04/04/2008 ELECTRIC - CABLE DROP CCLEMENS Approved IVRS - Inspection :*
04/04/2008 TEP CLEARANCE - AM JWEATHER Approved TEC CLEARED FOR ALL METERS PER C. CLEMENS
04/17/2008 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :*
05/02/2008 MECHANICAL - HOODS MRAMBER Approved
05/02/2008 MECHANICAL - FINAL MRAMBER Approved IVRS - Inspection :*
05/05/2008 ELECTRIC - FINAL CCLEMENS Approved IVRS - Inspection :*
CONTRACTOR WILL INSTALL ARC FAULT BREAKER FOR SMOKE DETECTOR AND REPLACE CRACKED BATHROOM COVER PLATE
05/05/2008 OUTDOOR LIGHTING FINAL CCLEMENS Approved
05/06/2008 ELECTRIC - UNDERGROUND CCLEMENS Approved
05/06/2008 ELECTRIC - OUTDOOR LIGHTING CCLEMENS Approved
05/07/2008 SITE - SEWER RMYERS Approved IVRS - Inspection :*
05/07/2008 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection :*
05/07/2008 PLUMBING - GAS PRESS TEST FNL RMYERS Approved IVRS - Inspection :*
05/07/2008 PLUMBING - ABOVE CEILING RMYERS Approved IVRS - Inspection :*
05/19/2008 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
1. CONTRACTOR TO INSTALL CLEANOUTS AT
KITCHEN SINKS (2)
2. CONTRACTOR TO INSTALL HAMMER ARRESTORS AT WASHER BOX
3. PLUMBING FINAL OK
05/19/2008 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection :*
05/19/2008 U VALUE FOR WINDOW AQUIROZ Approved IVRS - Inspection :*
05/19/2008 BUILDING ABOVE CEILING AQUIROZ Approved IVRS - Inspection :*
05/20/2008 PERMIT FINALED BFLORES Approved
05/20/2008 MECHANICAL - ABOVE CEILING MRAMBER Approved