Permit: T06CM01065
Permit Details
Apply Date:
02/22/2006
Applicant:
NORMAN AMY
Description:
NEW DUPLEX
Contractors:
- LE COCQ CONSTRUCTION COMPANY INC
Permit Reviews
Permit Number - T06CM01065
Permit Status: Final
Permit Description: NEW DUPLEX
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/10/2007 | RESUBMITTAL | 01/12/2007 | COMPLETED |
| 01/25/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 01/25/2008 | COMPLETED |
| 02/22/2006 | PLANS OK TO SUBMIT - RES 3RD PARTY | 02/22/2006 | COMPLETED |
| 02/22/2006 | 3RD PARTY REVIEW-RESIDENTIAL | 05/09/2006 | COMPLETED |
| 05/09/2006 | POST 3RD PARTY REVIEW | 05/30/2006 | COMPLETED |
| 05/30/2006 | RESUBMITTAL | 06/05/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM01065
Permit Status: Final
Permit Description: NEW DUPLEX
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/22/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T06CM01065
Permit Description: NEW DUPLEX
Total Completed Inspections - 35
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/09/2007 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* 1. ABS DWV UNDERGROUND OK TO COVER 2. WATER TEST, ONE RISER TO TEN FEET 3. CONTRACTOR TO USE CLEAN FILL AROUND PIPE |
| 05/11/2007 | ELECTRIC - UFER | RMAJUTA | Approved | IVRS - Inspection :* 1) #2 COPPER TO REBAR |
| 05/11/2007 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection :* |
| 05/11/2007 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection :* |
| 05/14/2007 | PLUMBING - PRE SLAB | RMYERS | Approved | IVRS - Inspection :* 1) OK FOR CONCRETE |
| 06/18/2007 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/18/2007 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/11/2007 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* OK TO COVER ALL AREAS GAS PRESSURE TEST OK |
| 07/11/2007 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection :* |
| 07/11/2007 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/16/2007 | ELECTRIC - INTERMEDIATE | RMAJUTA | Approved | IVRS - Inspection :* |
| 07/26/2007 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* DO NOT USE FLEX ON KITCHEN EXHAUST OK TO INSTALL VENT PIPE AFTER CABINETS ARE IN OK FOR SHEETROCK |
| 08/22/2007 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/31/2007 | STUCCO MESH | DWALKER | Approved | IVRS - Inspection :* |
| 04/01/2008 | ELECTRIC - CONSTRUCTION POWER | CCLEMENS | Approved | IVRS - Inspection :* |
| 04/01/2008 | ELECTRIC - ABOVE CEILING | CCLEMENS | Approved | IVRS - Inspection :* |
| 04/04/2008 | ELECTRIC - CABLE DROP | CCLEMENS | Approved | IVRS - Inspection :* |
| 04/04/2008 | TEP CLEARANCE - AM | JWEATHER | Approved | TEC CLEARED FOR ALL METERS PER C. CLEMENS |
| 04/17/2008 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :* |
| 05/02/2008 | MECHANICAL - HOODS | MRAMBER | Approved | |
| 05/02/2008 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
| 05/05/2008 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection :* CONTRACTOR WILL INSTALL ARC FAULT BREAKER FOR SMOKE DETECTOR AND REPLACE CRACKED BATHROOM COVER PLATE |
| 05/05/2008 | OUTDOOR LIGHTING FINAL | CCLEMENS | Approved | |
| 05/06/2008 | ELECTRIC - UNDERGROUND | CCLEMENS | Approved | |
| 05/06/2008 | ELECTRIC - OUTDOOR LIGHTING | CCLEMENS | Approved | |
| 05/07/2008 | SITE - SEWER | RMYERS | Approved | IVRS - Inspection :* |
| 05/07/2008 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :* |
| 05/07/2008 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | IVRS - Inspection :* |
| 05/07/2008 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection :* |
| 05/19/2008 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* 1. CONTRACTOR TO INSTALL CLEANOUTS AT KITCHEN SINKS (2) 2. CONTRACTOR TO INSTALL HAMMER ARRESTORS AT WASHER BOX 3. PLUMBING FINAL OK |
| 05/19/2008 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 05/19/2008 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |
| 05/19/2008 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 05/20/2008 | PERMIT FINALED | BFLORES | Approved | |
| 05/20/2008 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved |