Permit: T06CM00144
Permit Details
Apply Date:
01/10/2006
Applicant:
METRO PERMIT EXPRESS, INC *C
Description:
TI: MEDICAL OFFICE
Architects:
- LANCE, GEORGE GERARD
Contractors:
- CAYLOR CONSTRUCTION COMPANY , RO
Permit Reviews
Permit Number - T06CM00144
Permit Status: C of o
Permit Description: TI: MEDICAL OFFICE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/10/2006 | COMMERCIAL TI | 02/01/2006 | COMPLETED |
02/01/2006 | RESUBMITTAL | 02/07/2006 | COMPLETED |
02/07/2006 | RESUBMITTAL | 02/16/2006 | COMPLETED |
03/01/2006 | REVISION - - 1ST | 03/10/2006 | COMPLETED |
03/10/2006 | REVISION - - 1ST | 03/13/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM00144
Permit Status: C of o
Permit Description: TI: MEDICAL OFFICE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
01/10/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM00144
Permit Description: TI: MEDICAL OFFICE
Total Completed Inspections - 18
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/15/2006 | FRAMING | JCAGLE | Approved | IVRS - Inspection :* PLEASE PATCH ANY STEEL BEAMS OR COLUMNS WHERE FIREPROOFING MATERIAL WAS DAMAGED OR MISSING. |
03/15/2006 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* OK WALLS |
03/17/2006 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* AIR TEST WASTE & VENT TO POINT OF CONNECTION OK WATER PIPING OK 1. NEED TO SEE VENT TIE IWS OVERHEAD 2. NEED TO SEE CLOSET RINGS SECURED PROPERLY DEMO OK |
03/23/2006 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* |
03/29/2006 | MECHANICAL - FINAL | JMILITEL | Approved | OK FOR FINAL C OF O |
03/29/2006 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* 1. ACCESSIBLE RESTROOMS NORTH (115) & SOUTH (112) ARE MISSING VERTICAL GRAB BAR - SEE DETAILS F&G PAGE A3 |
03/29/2006 | FIRE - FINAL | LTHOMAS | Approved | |
03/29/2006 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
03/30/2006 | ENGINEERING - FINAL | JBRUCKME | Approved | |
03/31/2006 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* 1. PROPERLY SIZE GROUND CONNECTION IN JUNCTION BOX. 2. SUPPORT JUNCTION BOX. 3. OK FINAL |
03/31/2006 | PLUMBING - ABOVE CEILING | RRICH | Approved | IVRS - Inspection :* |
03/31/2006 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection :* |
03/31/2006 | SIGN - FINAL | JYBARRA | Approved | TENANTS ON DF ARE UP TO DATE; OK FOR C/O |
04/05/2006 | PLUMBING - ROUGH, SOIL | RRICH | Approved | PER PL FINAL |
04/05/2006 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* NOTE: YOUR EXISTING WATER HEATER PIPING & EXPANSION TANK ARE NOT PROPERLY SUPPORTED. THIS SHOULD BE DONE FOR BUILDING PROTECTION. THIS AREA IS SHOWN AS EXISTING ON APPROVED PLAN. |
04/05/2006 | PLUMBING - PROGRESS | RRICH | Approved | IVRS - Inspection :* |
04/05/2006 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* |
04/06/2006 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* |