Permit: T05PL02110
Permit Details
Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
8440 E TANQUE VERDE RD
Address NEW:
8440 E TANQUE VERDE RD
Apply Date:
12/27/2005
Applicant:
FRANCIS-MOULLIER CLAUDIA & MC GAHEY MARY JT/RS
Description:
REPL GAS LINE
Permit Reviews
Permit Number - T05PL02110
Permit Status: Final
Permit Description: REPL GAS LINE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/27/2005 | PLUMBING | 12/27/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05PL02110
Permit Status: Final
Permit Description: REPL GAS LINE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/27/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05PL02110
Permit Description: REPL GAS LINE
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/30/2005 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection : See detailed listing on site.| 999*SHALL PROVIDE THE REQUIRED TEST GAGE 15 LBS MAX WITH 1/10 INCREMENTS SHALL PROVIDE MIN OF 1" GAS SUPPLY TO EXISTING HOUSE CONNECTION. SHALL PROVIDE (2) 10 X10 LOUVER GRILLS LOCATED 12" BELOW CEILING AND 12" ABOVE FLOOR ON DOOR. SHALL PROVIDE A ROOF FLASHING ON ALL ROOF PENETRATIONS SHALL PROVIDE A AGA OR CSA GAS SHUT OFF VALVE @ WATER HTR LOCATED WITHIN 3" OF REGULATOR. SHALL PROVIDE WOOD BLOCKS WITH A 2 HOLE STRAPS FOR GAS LINE ON ROOF LOCATED EVERY 6' SHALL STRAP TO WALL GAS LINE EVERY 6' |
| 12/30/2005 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/30/2005 | PLUMBING - GAS PRESS TEST FNL | TRINIVJR | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 09/25/2006 | PERMIT FINALED | LJACKSON | Approved |