Permit: T05PL02110

Parcel: 11450002A

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
03/28/2006 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
14 PSI TEST IS OK -- LEFT GAS CARD
OK TO BACKFILL TRENCH
CORRECTIONS HAVE BEEN MADE
12/30/2005 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*SHALL PROVIDE THE REQUIRED TEST GAGE 15 LBS MAX WITH 1/10 INCREMENTS
SHALL PROVIDE MIN OF 1" GAS SUPPLY TO EXISTING HOUSE CONNECTION.
SHALL PROVIDE (2) 10 X10 LOUVER GRILLS LOCATED 12" BELOW CEILING AND 12" ABOVE FLOOR ON DOOR.
SHALL PROVIDE A ROOF FLASHING ON ALL ROOF PENETRATIONS
SHALL PROVIDE A AGA OR CSA GAS SHUT OFF VALVE @ WATER HTR LOCATED WITHIN 3" OF REGULATOR.
SHALL PROVIDE WOOD BLOCKS WITH A 2 HOLE STRAPS FOR GAS LINE ON ROOF LOCATED EVERY 6'
SHALL STRAP TO WALL GAS LINE EVERY 6'