Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address NEW:
8526 E TANQUE VERDE RD
Apply Date:
12/23/2005
Applicant:
CLAUDIA ALCANTAR
Description:
EXTEND GAS LINE
Contractors:
  • ALCANTAR DESIGN AND CONSTRUCTION SERVICES L L C

Permit Reviews

Permit Number - T05PL02097
Permit Status: Final
Permit Description: EXTEND GAS LINE
Start Date Submittal Complete Date Status  
12/23/2005 PLUMBING 12/23/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05PL02097
Permit Status: Final
Permit Description: EXTEND GAS LINE
Total Outstanding Activity Conditions - 1
Date Name
12/23/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T05PL02097
Permit Description: EXTEND GAS LINE
Total Completed Inspections - 2
Date Description Inspector Results Comments
12/30/2005 PLUMBING - GAS PRESSURE TEST TRINIVJR Approved IVRS - Inspection :
See detailed listing on site.| 999*SHALL PROVIDE THE REQUIRED TEST GAGE AND REQUIRED PRESSURE TEST 15 LBS MAX 1/10 INCREMENTS/ 3X THE WORKING PRESSURE
SHALL EXTEND FURNACE FLU VENT AND TERMINATE 2'-0" ABOVE COOLER WHEN FLU VENT IS LOCATED WITHIN 10' OF COOLER
SHALL EXTEND T & P DRAINS TO DAYLIGHT & REMOVE FLEX LINE
SHALL SECURE ALL GAS DROPS TO WALL
SHALL PROTECT ROMEX ELECTRICAL WIRE CONNECTION TO WATER HEATER.
SHALL CAP OFF WATER HTR FLU VENTS
07/13/2006 PERMIT FINALED LJACKSON Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW