Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/09/2006 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* 1) GAS PRESSURE TEST IS OK 2) ALL CORRECTIONS HAVE BEEN MADE 3) NOTE: CONTRACTOR SHALL PERM CAP PROPERLY FLUE VENT WYE FOR WATER HTR CONNECTION TO FURNACE FLU VENT AND SEAL T & P DRAIN PENTRATION |
|
| 01/08/2006 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* | |
| 01/06/2006 | PLUMBING - GAS PRESSURE TEST | Cancelled | CANCELLED PER CONTRACTOR DAVID #245-9797 | |
| 12/30/2005 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999*SHALL PROVIDE THE REQUIRED TEST GAGE AND REQUIRED PRESSURE TEST 15 LBS MAX 1/10 INCREMENTS/ 3X THE WORKING PRESSURE SHALL EXTEND FURNACE FLU VENT AND TERMINATE 2'-0" ABOVE COOLER WHEN FLU VENT IS LOCATED WITHIN 10' OF COOLER SHALL EXTEND T & P DRAINS TO DAYLIGHT & REMOVE FLEX LINE SHALL SECURE ALL GAS DROPS TO WALL SHALL PROTECT ROMEX ELECTRICAL WIRE CONNECTION TO WATER HEATER. SHALL CAP OFF WATER HTR FLU VENTS |
|
| 12/27/2005 | PLUMBING - GAS PRESSURE TEST | Cancelled | ||
| 12/27/2005 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* |