Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address NEW:
2133 E HIDALGO VISTA
Apply Date:
11/21/2005
Applicant:
ERIKA SOTO
Description:
NEW GAS LINE

Permit Reviews

Permit Number - T05PL01882
Permit Status: Final
Permit Description: NEW GAS LINE
Start Date Submittal Complete Date Status  
11/21/2005 PLUMBING 11/21/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05PL01882
Permit Status: Final
Permit Description: NEW GAS LINE
Total Outstanding Activity Conditions - 1
Date Name
11/21/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T05PL01882
Permit Description: NEW GAS LINE
Total Completed Inspections - 3
Date Description Inspector Results Comments
12/19/2005 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :
See detailed listing on site.| 999*NO ANSWER AT FRONT DOOR
PREVIOUS CORRECTIONS HAVE NOT BEEN MADE.
GAS INSPECTIONS HAVE NOT BEEN MADE.
GAS INSPECTION INCLUDES THE ENTIRE SYSTEM
ALL GAS APPLIANCES WILL NEED TO BE INSTALLED, VENTED PROPERLY AND INSPECTED.
PRESSURE TEST SHALL INCLUDE ALL PIPING
12/29/2005 PLUMBING - GAS PRESSURE TEST BBENEDON Approved IVRS - Inspection :
See detailed listing on site.| 999*
- PROVIDE BONDING OF GAS LINE THIS CAN BE ACCOMPLISHED BY INSTALLING A GROUND WIRE BETWEEN THE GAS AND WATER PIPING.
- PROVIDE A PRESSURE GAUGE WITH 1/10 POUND INCREMENTATION TEMP & PRESSURE RELIEF SHALL TERMINATE WITHOUT THREADS
WATER HEATER VENT REQUIRES A FLUE COLLAR.
- VENTING OUTSIDE OF ENCLOSURE REQUIRES DOUBLE WALL TYPE B VENT WITH A LISTED CAP.
- VENT SHALL EXTEND IN A GENERALLY VERTICAL DIRECTION WITH OFFSETS NOT EXCEEDING 45 DEG.
- B VENT REQUIRES 1" CLEARANCE FROM COMBUSTIBLES
- APPROVED VENT SUPPORTS DESIGNED FOR USE WITH B VENT REQUIRED. TIE WIRE IS NOT ACCEPTABLE.
- B VENTS TERMINATING LESS THAN 10' FROM THE COOLER ARE REQUIRED TO BE 3' ABOVE COOLER.
- PIPING PENETRATIONS SHALL BE SEALED.
* NOTE: PIPING & VENT INSIDE HOME AT FURNACE IS OK
STOVE IS ELECTRIC
07/24/2006 PERMIT FINALED LJACKSON Approved