Description:
Repair gas line
Contractors:
  • MAJOR CONSTRUCTION CO., LLC.

Outstanding Activity Conditions

Permit Number - T05PL01688
Permit Status: Expired
Permit Description: Repair gas line
Total Outstanding Activity Conditions - 1
Date Name
10/20/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T05PL01688
Permite Description: Repair gas line
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
10/21/2005 PLUMBING - GAS PRESSURE TEST N/A Not ready for Inspection IVRS - Inspection :*
10/21/2005 PLUMBING - FINAL N/A Not ready for Inspection IVRS - Inspection :*
1) WHERE UNIONS ARE NECESSARY LEFT-RIGHT NIPPLES AND COUPLINGS SHALL BE USED
2) PROVIDE AGA OR CSA APPROVED GAS VALVES AT ALL APPLIANCES WITH APPROVED GAS FLEXES
3) VENT FROM WATER HEATER TO BE DBL WALL THRU CEILING AND ROOF WITH APPROVED FLASHING TERMINATING 1' ABOVE ROOF MINIMUM WITH APPROVED VENT CAP
4) PROVIDE UPPER AND LOWER COMBUSTION AIR OPENINGS WITH LOUVERS MINIMUM 100 SQUARE INCHES EACH
5) CORRECT LOWER COMBUSTION AIR FOR FURNACE IN LOWER UNIT
6) PROVIDE 3-GALV SCREWS AT EACH JOINT OF APPLIANCE VENT PIPING
7) PROVIDE UPPER COMBUSTION AIR OF 100 SQUARE INCHES FOR FURNACE IN UPPER UNIT
8) PROVIDE BONDING OF BLDG GAS PIPING