Description:
REPL GAS LINE (APA)
Contractors:
  • CREECH'S PLUMBING *C

Outstanding Activity Conditions

Permit Number - T05PL01666
Permit Status: Expired
Permit Description: REPL GAS LINE (APA)
Total Outstanding Activity Conditions - 1
Date Name
10/17/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T05PL01666
Permite Description: REPL GAS LINE (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
10/18/2005 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PIPING CANNOT RUN IN RIGHT OF WAY. IT SHALL GO IMMEDIATELY ON TO PROPERTY
2) PIPING IS DAMAGED IN SEVERAL LOCATIONS
3) ALL PLASTIC GAS PIPING REQUIRES MINIMUM 18" COVER
4) WATER HEATER T & P DRIAN SHALL BE RIDGID PIPING GRAVITY DRAIN TO DAY LIGHT
5) PROVIDE 3-GALV SCREWS AT EACH JOINT OF WATER HEATER VENT PIPING
6) NO GAS PIPING SHALL BE UNDER GROUND UNDER A BLDG OR STRUCTURE
7) WHERE UNIONS ARE NECESSARY LEFT RIGHT NIPPLES AND COUPLINGS SHALL BE USED
8) PROVIDE BONDING OF BLDG GAS PIPING
9) VENT FROM WATER HEATER AND FURNACE WHEN WITHIN 10' OF COOLER INTAKE TO BE 3' WATER HEATER, 2' FURNACE ABOVE TOP OF COOLER INTAKE