Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
COMMERCIAL OTHER
Address:
222 E 5TH ST
Address NEW:
222 E 5TH ST
Apply Date:
09/08/2005
Applicant:
TUCSON PLUMBING SERVICE ,
Description:
REPLACE: RAIN DRAIN
Contractors:
  • TUCSON PLUMBING & HEATING INC *C
  • TUCSON PLUMBING SERVICE ,

Permit Reviews

Permit Number - T05PL01430
Permit Status: Expired
Permit Description: REPLACE: RAIN DRAIN
Start Date Submittal Complete Date Status  
09/13/2005 PLUMBING 03/31/2006 STOPPED Review Details

Outstanding Activity Conditions

Permit Number - T05PL01430
Permit Status: Expired
Permit Description: REPLACE: RAIN DRAIN
Total Outstanding Activity Conditions - 1
Date Name
09/08/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T05PL01430
Permite Description: REPLACE: RAIN DRAIN
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
09/12/2005 PLUMBING - ROOF DRAINS N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE CITY APPROVED PLAN FOR ROOF DRAINS. THIS ROOF IS APP. 75' X 150' WITH 3-4" DRAINS ONLY ON A 6" DRAIN SYSTEM AND 2-4" DRAINS ONLY ON A 4" DRAIN SYSTEM. THERE IS NO OVERFLOW DRAINAGE, SCUPPERS, OR GUTTER SYSTEM. ROOF HAS PARAPIT ON ALL SIDES
2) PROVIDE LONG RADIUS DRAINAGE FITTINGS
3) SUPPORT ALL PIPING AT CHANGES OF DIRECTION AND AT BOTH ENDS OF HORIZONTAL PIPING AT JOINTS
4) PROVIDE AIR OR WATER TEST ON SYSTEM