Permit: T05PL01338
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
7318 E CALLE CUERNAVACA
Address NEW:
7318 E CALLE CUERNAVACA
Apply Date:
08/17/2005
Applicant:
MELTON PLUMBING SERVICE,*C
Description:
GAS LINE (APA)
Contractors:
- MELTON PLUMBING SERVICE,*C
Outstanding Activity Conditions
Permit Number - T05PL01338
Permit Status: Expired
Permit Description: GAS LINE (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/17/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T05PL01338
Permite Description: GAS LINE (APA)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/18/2005 | PLUMBING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE BONDING OF BLDG GAS PIPING 2) WATER HEATER TEMPERATURE AND PRESSURE RELIEF PIPING TO BE RIDGID APPROVED MATERIAL GRAVITY DRAIN TO DAYLIGHT TERMINATING 90 DEGREE DOWN 6"-24" FROM FINISH GRADE 3) VENT FROM WATER HEATER TO BE 3' ABOVE TOP OF INTAKE FROM COOLER WHEN WITHIN 10' OF INTAKE WITH APPROVED VENT MATERIAL |
Completed Inspections
Permit Status: Expired
Permit Number: T05PL01338
Permit Description: GAS LINE (APA)
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/18/2005 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* 1) 15 PSI TEST NEW PIPING ABOVE GRADE TO EXISTING SERVICE ENTRANCE TO WATER HEATER AND FURNACE OK. GAS CARD AT METER |