Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Apply Date:
08/17/2005
Applicant:
MELTON PLUMBING SERVICE,*C
Description:
GAS LINE (APA)
Contractors:
  • MELTON PLUMBING SERVICE,*C

Outstanding Activity Conditions

Permit Number - T05PL01338
Permit Status: Expired
Permit Description: GAS LINE (APA)
Total Outstanding Activity Conditions - 1
Date Name
08/17/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T05PL01338
Permite Description: GAS LINE (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
08/18/2005 PLUMBING - FINAL N/A Not ready for Inspection IVRS - Inspection :*
1) PROVIDE BONDING OF BLDG GAS PIPING
2) WATER HEATER TEMPERATURE AND PRESSURE RELIEF PIPING TO BE RIDGID APPROVED MATERIAL GRAVITY DRAIN TO DAYLIGHT TERMINATING 90 DEGREE DOWN 6"-24" FROM FINISH GRADE
3) VENT FROM WATER HEATER TO BE 3' ABOVE TOP OF INTAKE FROM COOLER WHEN WITHIN 10' OF INTAKE WITH APPROVED VENT MATERIAL

Completed Inspections

Permit Status: Expired
Permit Number: T05PL01338
Permit Description: GAS LINE (APA)
Total Completed Inspections - 1
Date Description Inspector Results Comments
08/18/2005 PLUMBING - GAS PRESSURE TEST RRICH Approved IVRS - Inspection :*
1) 15 PSI TEST NEW PIPING ABOVE GRADE TO EXISTING SERVICE ENTRANCE TO WATER HEATER AND FURNACE OK. GAS CARD AT METER

Documents

File Name Document Type  
None DOCUMENTS VIEW