Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address NEW:
6981 S SANTA CLARA AV
Apply Date:
07/07/2005
Applicant:
ARMANDO MARQUEZ
Description:
NEW GAS LINE

Outstanding Activity Conditions

Permit Number - T05PL01125
Permit Status: Final
Permit Description: NEW GAS LINE
Total Outstanding Activity Conditions - 1
Date Name
07/07/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T05PL01125
Permit Description: NEW GAS LINE
Total Completed Inspections - 4
Date Description Inspector Results Comments
07/14/2005 PLUMBING - FINAL TRINIVJR Approved IVRS - Inspection :*
1) GAS PRESSURE TEST OK
2) GAS SHUT OFF VALVES OK
3) WATER HTR FLUE VENT, T & P VALVE AND DRAIN IS OK
4) FURNACE FLU VENT OK
5) NOTE: SHALL REMOVE THE MECHANICAL TAPE AROUND THE DBL WALL FLUE VENT SO IT MAY BREATH
07/14/2005 PLUMBING - GAS PRESSURE TEST TRINIVJR Approved
07/14/2005 PLUMBING - GAS PRESSURE TEST TRINIVJR Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) SHALL PROVIDE 2-10 X 10 MINIMUM LOUVER GRILLS LOCATED 12" BELOW CEILING AND 12" ABOVE FLOOR ON MECH. ROOM DOOR FOR COMBUSTION AIR
2) SHALL PROVIDE (3) SHEET METAL SCREWS PER JOINT FOR WATER HTR FLU VENT AND AT APPLIANCE COLLAR
3) SHALL PLUG AND REPLACE GAS SHUT OFF VALVE WITH AGA OR CSA VALVE AND PLUG THE END IF NO APPLIANCE IS AVAILABLE AT TIME OF INSPECTION
4) SHALL MAINTAIN MINIMUM OF 12" OF COVER FOR GAS LINE.
SOME AREAS APPEAR TO BE SHALLOW
07/18/2005 PERMIT FINALED JWEATHER Approved