Permit: T05PL01034
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
7734 E POINCIANA DR
Address NEW:
7734 E POINCIANA DR
Apply Date:
06/16/2005
Applicant:
M L COLLINS INC *C
Description:
REPAIR:GAS LINE (APA)
Contractors:
- M L COLLINS INC *C
Outstanding Activity Conditions
Permit Number - T05PL01034
Permit Status: Expired
Permit Description: REPAIR:GAS LINE (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/16/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T05PL01034
Permite Description: REPAIR:GAS LINE (APA)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/17/2005 | PLUMBING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* NOT READY 1. PROVIDE BONDING OF BUILDING GAS PIPING. 2) VENT FROM WATER HEATER TO BE 3', VENT FROM FURNACE TO BE 2' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE. |
Completed Inspections
Permit Status: Expired
Permit Number: T05PL01034
Permit Description: REPAIR:GAS LINE (APA)
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/17/2005 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* 12 PSI AIR TEST FROM METER 1 1/4 BLK IRON PIPE TRANSITION TO BE UNDERGROUND TO 1 1/4 BUC INTO BUILDING TO EXISITING TO STOVE, WATER HEATER, AND FURNACE ONLY. APPROVED |