Permit: T05PL00969
Permit Details
Apply Date:
06/03/2005
Applicant:
CORONADO PLUMBING SERVICE AND REPAIR
Description:
REPLACE:GAS LINE
Contractors:
- CORONADO PLUMBING SERVICE AND REPAIR
Outstanding Activity Conditions
Permit Number - T05PL00969
Permit Status: Final
Permit Description: REPLACE:GAS LINE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/03/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05PL00969
Permit Description: REPLACE:GAS LINE
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/20/2005 | PLUMBING - GAS PRESSURE TEST | JMILITEL | Approved | IVRS - Inspection :* 15 PSI TEST IS OK. RELOCATE GAS SHUT OFF VALVE @ WATER HEATER BEFORE THE FLEX CONNECTOR. PROVIDE DOUBLE WALL VENT PIPE & CAP ON WATER HEATER VENT. PROVIDE MIN 1 " CLEARANCE AT ROOF PENETRATION. PROVIDE T & P RELIEF DRAIN PIPE. RECALL FOR FINAL INSPECTION. |
| 06/24/2005 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection :* 1) ALL CORRECTIONS HAVE BEEN MADE. |
| 06/27/2005 | PERMIT FINALED | JKOZUCH | Approved |