Permit: T05PL00968
Permit Details
Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
5713 S SOUTHLAND BL
Address NEW:
5713 S SOUTHLAND BL
Apply Date:
06/03/2005
Applicant:
JESUS ALMAZAN
Description:
RELOCATE GAS METER
Permit Reviews
Permit Number - T05PL00968
Permit Status: Final
Permit Description: RELOCATE GAS METER
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/03/2005 | PLUMBING | 06/03/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05PL00968
Permit Status: Final
Permit Description: RELOCATE GAS METER
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/03/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05PL00968
Permit Description: RELOCATE GAS METER
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/13/2005 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) SHALL EXTEND T & P DRAINS TO DAYLIGHT FULL SIZE 3/4" FOR WATER HTR. DO NOT USE A FLEX LINE. 2) SHALL PROVIDE ( 3) SHEET METAL SCREWS PER JOINT @ WATER HTR FLU VENT. 3) SHALL PROVIDE COMBUSTION RELIEF MIN 10'' X 10" LOUVER GRILLS LOCATED 12" ABOVE FLOOR AND 12" BELOW CEILINGS FOR WATER HTR ROOM AND FURNACE ROOM. THESE GRILLS MAY BE LOCATED ON THE DOOR. 4) SHALL LOCATE GAS SHUT OFF VALVE MIN 3' _ 0" FROM REGULATOR @ WATER HEATER @ SMALL UNIT. 5) SHALL EXTEND FURNACE FLU VENT MIN OF 2" ABOVE COOLER. 6) SHALL PROVIDE FLU VENT CAP FOR WATER HTR FRONT UNIT. |
| 06/13/2005 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 04/11/2006 | PERMIT FINALED | BFLORES | Approved |