Permit: T05PL00439
Permit Details
Apply Date:
03/07/2005
Applicant:
CUMMINGS PLUMBING INC , *C
Description:
REPLACE:GASLINE:WATER HEATER (APA)
Contractors:
- CUMMINGS PLUMBING INC , *C
Outstanding Activity Conditions
Permit Number - T05PL00439
Permit Status: Final
Permit Description: REPLACE:GASLINE:WATER HEATER (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/07/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05PL00439
Permit Description: REPLACE:GASLINE:WATER HEATER (APA)
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/09/2005 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | |
| 03/09/2005 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection :* 1) GAS PRESSURE TEST IS OK. 2) GAS SHUT OFF VALVES OK. 3) WATER HTR FLU VENT, T & P VALVE & DRAIN IS OK. 4) GAS PACK ON ROOF IS OK. 5) OK TO BACKFILL TRENCH. |
| 03/09/2005 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) SHALL PROVIDE BONDING TO GAS SYSTEM @ ELECTRICAL PANEL OR TO GROUNDED WATER WITH MIN #6 WIRE. 2) SHALL OBTAIN A WATER HTR PERMIT. 3) SHALL PROVIDE ( 3) SHEET METAL SCREWS PER JOINT @ WATER HTR FLU VENT CONNECTOR AND @ APPLIANCE COLLAR. 4) SHALL APPLY TAPER PRIMER AND 10 MIL TAPE @ METER GAS RISER & WRENCH MARKS. 5) SHALL PROVIDE REQUIRED TEST GAGE. 6) SHALL PROVIDE TWO HOLE STRAP ON ROOF. |
| 03/10/2005 | PERMIT FINALED | JKOZUCH | Approved |