Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Final
Type:
SIGN PERMIT
Apply Date:
10/06/2005
Applicant:
FLUORESCO LIGHTING MAINTENANCE**C
Description:
SIGN: 9841 ALDO
Contractors:
  • FLUORESCO LIGHTING MAINTENANCE**C

Completed Inspections

Permit Status: Final
Permit Number: T05OT02490
Permit Description: SIGN: 9841 ALDO
Total Completed Inspections - 5
Date Description Inspector Results Comments
10/07/2005 SIGN SITE REVIEW JYBARRA Approved IVRS - Inspection :*
10/20/2005 SIGN INSPECTION JYBARRA Approved IVRS - Inspection :*
10/24/2005 SIGN SHOP RHOLLAND Approved IVRS - Inspection :*
1) ACCESS TO BE AS PER 600.21-CANNOT ACCESS POWER SUPPLIES. ACCESS HOLE TO HAVE CLEAR ACCESS
2) BOND METAL LETTERS AND FITTINGS AT LEXAN SURFACE
3) A MARKING LABEL IS NEEDED 600.4
4) SWITCH TO BE AS PER 600.6
5) MAINTAIN 1 1/2" FROM NEON RACEWAY WITH BONDING CONDUCTOR
6) SIGN NOT TO BE ENERGIZED UNTIL FINALED BY ELECTRICAL INSPECTOR
10/24/2005 SIGN ELECTRIC RHOLLAND Approved IVRS - Inspection :*
05/18/2006 PERMIT FINALED LJACKSON Approved