Inspection Status: Approved
Inspection History: SIGN SHOP
Permit Number - T05OT02490
Inspection Description - SIGN SHOP
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/27/2006 | SIGN SHOP | Approved | IVRS - Inspection :* | |
10/24/2005 | SIGN SHOP | Not ready for Inspection | IVRS - Inspection :* 1) ACCESS TO BE AS PER 600.21-CANNOT ACCESS POWER SUPPLIES. ACCESS HOLE TO HAVE CLEAR ACCESS 2) BOND METAL LETTERS AND FITTINGS AT LEXAN SURFACE 3) A MARKING LABEL IS NEEDED 600.4 4) SWITCH TO BE AS PER 600.6 5) MAINTAIN 1 1/2" FROM NEON RACEWAY WITH BONDING CONDUCTOR 6) SIGN NOT TO BE ENERGIZED UNTIL FINALED BY ELECTRICAL INSPECTOR |
|
10/20/2005 | SIGN SHOP | Denied | IVRS - Inspection : There is no access to the site.| 920* |