Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SIGN PERMIT
Apply Date:
10/06/2005
Applicant:
FLUORESCO LIGHTING MAINTENANCE**C
Description:
SIGN: 9841 ALDO
Contractors:
  • FLUORESCO LIGHTING MAINTENANCE**C

Completed Inspections

Permit Status: Final
Permit Number: T05OT02490
Permit Description: SIGN: 9841 ALDO
Total Completed Inspections - 5
Date Description Inspector Results Comments
10/07/2005 SIGN SITE REVIEW JYBARRA Approved IVRS - Inspection :*
10/20/2005 SIGN INSPECTION JYBARRA Approved IVRS - Inspection :*
10/24/2005 SIGN SHOP RHOLLAND Approved IVRS - Inspection :*
1) ACCESS TO BE AS PER 600.21-CANNOT ACCESS POWER SUPPLIES. ACCESS HOLE TO HAVE CLEAR ACCESS
2) BOND METAL LETTERS AND FITTINGS AT LEXAN SURFACE
3) A MARKING LABEL IS NEEDED 600.4
4) SWITCH TO BE AS PER 600.6
5) MAINTAIN 1 1/2" FROM NEON RACEWAY WITH BONDING CONDUCTOR
6) SIGN NOT TO BE ENERGIZED UNTIL FINALED BY ELECTRICAL INSPECTOR
10/24/2005 SIGN ELECTRIC RHOLLAND Approved IVRS - Inspection :*
05/18/2006 PERMIT FINALED LJACKSON Approved