Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Withdrwn
Type:
COMMERCIAL OTHER
Address:
8001 E TIMROD ST
Address NEW:
8001 E TIMROD ST
Apply Date:
08/30/2005
Applicant:
TIMROD HOME CARE
Description:
C OF O:ADULT CARE HOME

Permit Reviews

Permit Number - T05OT02149
Permit Status: Withdrwn
Permit Description: C OF O:ADULT CARE HOME
Start Date Submittal Complete Date Status  
08/30/2005 C OF O 09/08/2005 COMPLETED Review Details

Outstanding Inspections

Permit Status: Withdrwn
Permit Number: T05OT02149
Permite Description: C OF O:ADULT CARE HOME
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
10/19/2005 BUILDING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ORIGINAL PLANS FOR ADDITION IN 1995 REMODEL DO NOT SHOW LAUNDRY, BEDROOMS ON WEST SIDE, KITCHEN ? AT NE BEDROOM. FILLED IN DOORS ETC...
2) R-3 OCCUPANCY 5 CLIENTS MAXIMUM
3) ALL BEDROOMS REQUIRE SMOKE DETECTORS
4) BARS OVER EMERGENCY EGRESS WINDOWS MUST OPEN WITH NO SPECIAL KNOWLEDGE, TOOLS, NOR PINCHING AND TWISTING
5) WATER HEATER LACKS PROPER COMBUSTION SUPPLY/RELIEF AND TPRV
6) FURNACE AND WATER HEATER EXHAUST VENTS IMPROPERLY MADE UP AND LACK PROPER CLEARANCE TO COMBUSTIBLE MATERIALS
7) GROUND FACE UNION ON GAS LINE IN FURNACE CLOSET DOES NOT MEET CODE REQUIREMENTS
8) NO DBL KEYED DEAD BOLTS ALLOWED ON EXIT DOORS
10/19/2005 FIRE - FINAL N/A Denied NEED SMOKE DETECTORS IN BEDROOMS & OUTSIDE OF BEDROOMS. NEED TO FIX QUICK RELEASES FOR WROUGHT IRON ON BEDROOM WINDOWS

Completed Inspections

Permit Status: Withdrwn
Permit Number: T05OT02149
Permit Description: C OF O:ADULT CARE HOME
Total Completed Inspections - 1
Date Description Inspector Results Comments
09/13/2005 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*

Documents

File Name Document Type  
None DOCUMENTS VIEW