Inspection History Details
Inspection Status: Denied
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/19/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ORIGINAL PLANS FOR ADDITION IN 1995 REMODEL DO NOT SHOW LAUNDRY, BEDROOMS ON WEST SIDE, KITCHEN ? AT NE BEDROOM. FILLED IN DOORS ETC... 2) R-3 OCCUPANCY 5 CLIENTS MAXIMUM 3) ALL BEDROOMS REQUIRE SMOKE DETECTORS 4) BARS OVER EMERGENCY EGRESS WINDOWS MUST OPEN WITH NO SPECIAL KNOWLEDGE, TOOLS, NOR PINCHING AND TWISTING 5) WATER HEATER LACKS PROPER COMBUSTION SUPPLY/RELIEF AND TPRV 6) FURNACE AND WATER HEATER EXHAUST VENTS IMPROPERLY MADE UP AND LACK PROPER CLEARANCE TO COMBUSTIBLE MATERIALS 7) GROUND FACE UNION ON GAS LINE IN FURNACE CLOSET DOES NOT MEET CODE REQUIREMENTS 8) NO DBL KEYED DEAD BOLTS ALLOWED ON EXIT DOORS |
|
| 09/13/2005 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* PLEASE HAVE PLANS AND PERMITS AT SITE |