Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T05OT00678
Permit Details
Apply Date:
03/29/2005
Applicant:
BOB'S NEON
Description:
SIGN: 8744 SAFE Q CREDIT UNION
Contractors:
- BOB'S NEON
Outstanding Inspections
Permit Status: Closed
Permit Number: T05OT00678
Permite Description: SIGN: 8744 SAFE Q CREDIT UNION
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/13/2005 | SIGN SHOP | N/A | Not ready for Inspection | IVRS - Inspection :* |
04/13/2005 | SIGN ELECTRIC | N/A | Not ready for Inspection | IVRS - Inspection :*1) ISOLATE PRIMARY POWE TO SWICH IN SIGN. 2) BOND RACEWAY. 3) A JUNCTION BOX IS NEEDED- WE HAVE EXPOSED CONDUCTORS AND OPEN SPLICES. 4) A MARKING LABEL IS NEEDED. 5) PLEASE HAVE PLANS AND PERMITS ON SITE. 6) USE APPROVED CONNECTORS AND WIRING METHODS. 7) SUPPORT GTO CABLE 1 1/2" -SPAGATTI GLASS IS NOT AN INSULATOR. 8) MISISNG RACE WAY COVERS. 9) PROPERLY TERMINATE HIGH VOLTAGE CONNEC |
Completed Inspections
Permit Status: Closed
Permit Number: T05OT00678
Permit Description: SIGN: 8744 SAFE Q CREDIT UNION
Total Completed Inspections - 2
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/30/2005 | SIGN SITE REVIEW | JSONKIN | Approved | IVRS - Inspection :* |
10/16/2006 | SIGN INSPECTION | JSONKIN | Approved |