Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
6901 E 2ND ST
Address NEW:
6901 E 2ND ST
Apply Date:
08/16/2005
Applicant:
D AND H AIR CONDITIONING CO,*C
Description:
REPL 4TON SPLIT SYSTEM (APA)
Contractors:
  • D AND H AIR CONDITIONING CO,*C

Outstanding Activity Conditions

Permit Number - T05ME00573
Permit Status: Expired
Permit Description: REPL 4TON SPLIT SYSTEM (APA)
Total Outstanding Activity Conditions - 1
Date Name
08/16/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T05ME00573
Permite Description: REPL 4TON SPLIT SYSTEM (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
08/17/2005 MECHANICAL - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE A MINIMUM 1/4" PER FT SLOPE ON FURNACE VENT CONNECTOR
2) FURNACE IS BLOCKING REMOVAL OF WATER HEATER
3) FITTERS CANNOT BE REMOVED
4) VENT IS BLOCKING ACCESS TO AIR CLEANER
5) GAS IS LEAKING INSIDE FURNACE ROOM POSSIBLY FROM OLD SHUT OFF VALVE
6) PROVIDE A HIGH COMBUSTION AIR OPENING

Documents

File Name Document Type  
None DOCUMENTS VIEW