Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
2001 E SPRING ST
Address NEW:
2001 E SPRING ST
Apply Date:
12/20/2005
Applicant:
BAKER MICHAEL
Description:
panel upgrade 100amp to 150amp
Contractors:
  • ALL RESIDENTIAL AND COMMERCIAL ELECTRIC LLC *T

Outstanding Activity Conditions

Permit Number - T05EL02506
Permit Status: Final
Permit Description: panel upgrade 100amp to 150amp
Total Outstanding Activity Conditions - 1
Date Name
12/20/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T05EL02506
Permit Description: panel upgrade 100amp to 150amp
Total Completed Inspections - 3
Date Description Inspector Results Comments
12/28/2005 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) PROPERLY SUPPORT RISER ABOVE PANEL
2) INSTALL GROUNDING ELECTRODE CONDUCTOR BEHIND PIPING AND TO STRUCTURE. GROUNDING ELECTRODE TO BE AS CLOSE AS POSSIBLE TO SERVICE 250.30(A)(4)
3) SUPPORT CONDUITS AND TIGHTEN LOOSE FITTINGS
4) GROUND JUNCTION BOXES
5) MISSING LB COVER
6) APPROVED FITTINGS AND SEALING DEVICES NEEDED
7) PLEASE LABEL ALL BREAKERS
8) OLD DISCONNECT NOT TO BE USED AT JUNCTION BOX
9) FITTING TO BE FOR WEATHER PROOF LOCATION
01/05/2006 TEP CLEARANCE - PM JWEATHER Approved CLEAR INCR PER R. MAJUTA
07/11/2006 PERMIT FINALED LJACKSON Approved