Permit: T05EL02501
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
220 W LINCOLN ST #02
Address NEW:
220 W LINCOLN ST #02
Apply Date:
12/19/2005
Applicant:
WILKOWSKI ELECTRIC *C
Description:
ELEC UPGRADE 100AMPS (APA) REV1:REWIRE UNIT#2 &ADD SMOKE DETECTORS TO UNIT #1 EXTENDED PERMIT FOR ELECTRIC RECONNECT #2 AND #3
Contractors:
- WILKOWSKI ELECTRIC *C
Permit Reviews
Permit Number - T05EL02501
Permit Status: Expired
Permit Description: ELEC UPGRADE 100AMPS (APA)
REV1:REWIRE UNIT#2 &ADD SMOKE DETECTORS TO UNIT #1
EXTENDED PERMIT FOR ELECTRIC RECONNECT #2 AND #3
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/25/2006 | OTHER | 05/25/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05EL02501
Permit Status: Expired
Permit Description: ELEC UPGRADE 100AMPS (APA)
REV1:REWIRE UNIT#2 &ADD SMOKE DETECTORS TO UNIT #1
EXTENDED PERMIT FOR ELECTRIC RECONNECT #2 AND #3
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/19/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T05EL02501
Permite Description: ELEC UPGRADE 100AMPS (APA)
REV1:REWIRE UNIT#2 &ADD SMOKE DETECTORS TO UNIT #1
EXTENDED PERMIT FOR ELECTRIC RECONNECT #2 AND #3
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/09/2006 | ELECTRIC - UNDERGROUND | N/A | Partial Approval | IVRS - Inspection :* |
| 11/08/2006 | ELECTRIC - INTERMEDIATE | N/A | Partial Approval | IVRS - Inspection :* |
| 12/30/2005 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. USE SPLIT BOLT OUTSIDE OF SERVICE PANEL TO TAP GROUNDING ELECTRODE CONDUCTOR TO SECOND SERVICE. 2. GAS & WATER TO BOTH UNITS TO BE BONDED. 3. VERIFY PERMITS & PLANS FOR INSIDE NEW WIRING, IF NOT PLEASE OBTAIN, NO POWER CLEARANCE FOR SERVICES UNTIL NEW WIRING FOR BOTH UNITS HAS BEEN PERMITTED & INSPECTED. THIS ALSO APPLIES TO WASHROOM BLD. 4. USE SCH 80 PVC WHERE EXPOSED BELOW SERVICES 5. DERATE BRANCH CIRCUITS IN 1 1/2" CONDUITS TO UNIT #2 PER NEC |
Completed Inspections
Permit Status: Expired
Permit Number: T05EL02501
Permit Description: ELEC UPGRADE 100AMPS (APA)
REV1:REWIRE UNIT#2 &ADD SMOKE DETECTORS TO UNIT #1
EXTENDED PERMIT FOR ELECTRIC RECONNECT #2 AND #3
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/21/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | INCR CLEARED FOR #2 & #3 PER D. SANTACRUZ |