Permit: T05EL02388
Permit Details
Apply Date:
12/02/2005
Applicant:
N/A
Description:
RELOCATE ELEC TO UG FROM OH
Contractors:
- COSEC LAND DEVELOPMENT L L C
Permit Reviews
Permit Number - T05EL02388
Permit Status: Expired
Permit Description: RELOCATE ELEC TO UG FROM OH
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
12/02/2005 | ELECTRICAL | 12/02/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05EL02388
Permit Status: Expired
Permit Description: RELOCATE ELEC TO UG FROM OH
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
12/02/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T05EL02388
Permite Description: RELOCATE ELEC TO UG FROM OH
Total Outstanding Inspections - 4
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/22/2006 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : The service is not per code.| 210* 1. INSTALL ADDRESS ON SERVICE 2. SEPARATE GROUNDS & NEUTRALS @ SUB-PANEL 3. PROVIDE HOLD DOWN KIT FOR SUB-PANEL MAIN 4. IDENTIFY ALL BREAKERS - SERVICE & SUB-PANEL |
05/26/2006 | ELECTRIC - INTERMEDIATE | N/A | Not ready for Inspection | IVRS - Inspection :* |
12/20/2005 | ELECTRIC - UNDERGROUND | N/A | Partial Approval | IVRS - Inspection :* 1) UNDERGROUND 1 1/4" PVC FROM 1216 TO REAR UNIT SERVICE LOCATION APPROVED 2) 2 GROUND ROD WITH #4 CU TO EXISTING 1216 SERVICE OK |
12/20/2005 | ELECTRIC - CABLE DROP | N/A | Not ready for Inspection | IVRS - Inspection :* |
Completed Inspections
Permit Status: Expired
Permit Number: T05EL02388
Permit Description: RELOCATE ELEC TO UG FROM OH
Total Completed Inspections - 1
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/12/2006 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO |