Permit: T05EL02376
Permit Details
Apply Date:
11/29/2005
Applicant:
TECHNICIANS FOR SUSTAINABILITY L L C *C
Description:
ELEC UPGRADE 200AMPS
Contractors:
- TECHNICIANS FOR SUSTAINABILITY L L C *C
Outstanding Activity Conditions
Permit Number - T05EL02376
Permit Status: Final
Permit Description: ELEC UPGRADE 200AMPS
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/29/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05EL02376
Permit Description: ELEC UPGRADE 200AMPS
Total Completed Inspections - 5
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/16/2005 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* |
| 12/19/2005 | TEP CLEARANCE - AM | JKOZUCH | Approved | INCR |
| 12/23/2005 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection : The service is not per code.| 210*NEED PERMANENT ADDRESS LABEL IDENTIFY PANEL DIRECTORY BONDING FOR GAS AND WATER NEEDS TO BE # 4 CU MIN HAVE OPEN L.B @ CARPORT NEED MAX 15 AMP BREAKER ON 126A KNOB & TUBE WIRING ( CLAD) GROUND FIRE PLACE OUTLET BOX GROUND J-BOX ENCLOSURE PROPERLY ( NO S?IF TAP SCREW) |
| 01/09/2006 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection :* |
| 01/10/2006 | PERMIT FINALED | JKOZUCH | Approved |