Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
745 W CALLE MEDINA
Apply Date:
09/08/2005
Applicant:
STEPHEN ANDERSON
Description:
RE-CONNECT: ELECTRICAL & UPGRADE

Outstanding Activity Conditions

Permit Number - T05EL01850
Permit Status: Expired
Permit Description: RE-CONNECT: ELECTRICAL & UPGRADE
Total Outstanding Activity Conditions - 1
Date Name
09/08/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T05EL01850
Permite Description: RE-CONNECT: ELECTRICAL & UPGRADE
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
09/09/2005 ELECTRIC - RECONNECT N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
10/26/2005 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1) CHANGE PERMIT DESCRIPTION TO SERVICE UPGRADE
2) INSTALL 2 GROUND RODS 6' MINIMUM APART
3) BOND WATER AND GAS PIPING
4) INSTALL BOND BUSHING AT TERMINATION WHEN USING RE-WASHERS AT PANEL
5) SUPPORT RISER CONDUIT WITHIN 3' OF PANEL-USE 1/4" BOLTS
6) CALLED LEFT MESSAGE TO APPLICANT

Completed Inspections

Permit Status: Expired
Permit Number: T05EL01850
Permit Description: RE-CONNECT: ELECTRICAL & UPGRADE
Total Completed Inspections - 2
Date Description Inspector Results Comments
11/01/2005 ELECTRIC - SERVICE UPGRADE RMAJUTA Approved IVRS - Inspection :*DRIVE GROUND RODS TO GRADE OR BELOW TO AVOID TRIP HAZARD
11/02/2005 TEP CLEARANCE - AM JKOZUCH Approved INC