Permit: T05EL00531
Permit Details
Apply Date:
03/18/2005
Applicant:
EDWARD MANUEL
Description:
RECONNECT:ELECTRIC:SFR
Outstanding Activity Conditions
Permit Number - T05EL00531
Permit Status: Expired
Permit Description: RECONNECT:ELECTRIC:SFR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/18/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T05EL00531
Permite Description: RECONNECT:ELECTRIC:SFR
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/24/2005 | ELECTRIC - RECONNECT | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 03/24/2005 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FRONT PORCH LIGHT FIXTURE TO BE REPLACED, WIRES CUT. 2) MIDDLE CARPORT FIXTURE HANGING ON WIRE. 3) WATER HEATER CIRCUIT- CONDUCTORS GOING INTO CIRCUIT BREAKER-BOTTOM ONE-BURNT COPPER & LOOSE-NEEDS TO BE CUT BACK RESTRIPPED & RE LANDED. 4) REPLACE BROKEN RECEPTACLE BY REAR DOOR INSIDE. 5) INSTALL ALL MISSING OR BROKEN RECEPTACLE COVERS. 6) LIGHT IN WASH ROOM NEEDS A J-BOX BEHIND IT AND TO BE INSTALLED. 7) RECEPTACLES SUCH AS IN LIVING ROOM CANNOT HAVE GROUNDS TIED TO NEUTRALS AND WHERE THERE ARE NO/ GROUNDS IN RECEPTACLES THEY MUST BE OF A TWO HOLE TYPE. 8) WATER HEATER J-BOX NEEDS COVER, THE WATER HEATER WIRING ALSO NEEDS COVER. 9) SMOKE DETECTORS REQUIRED IN BEDROOMS, BATTERY OK SEE LISTING FOR INSTALLATION INSTRUCTIONS ON LOCATIONS |