Permit: T05CM05790
Permit Details
Apply Date:
11/18/2005
Applicant:
H S P TUCSON INC
Description:
SFR TD # 16-43-48 R1- Truss repair
Contractors:
- H S P TUCSON INC
Permit Reviews
Permit Number - T05CM05790
Permit Status: Final
Permit Description: SFR TD # 16-43-48
R1- Truss repair
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/03/2006 | REVISION - WALK THRU | 02/03/2006 | COMPLETED |
| 05/05/2006 | REVISION - - 2ND | 05/09/2006 | COMPLETED |
| 11/18/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 11/22/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM05790
Permit Status: Final
Permit Description: SFR TD # 16-43-48
R1- Truss repair
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/18/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05CM05790
Permit Description: SFR TD # 16-43-48
R1- Truss repair
Total Completed Inspections - 38
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/10/2006 | PLUMBING - ROUGH, SOIL | HPEDROZA | Approved | IVRS - Inspection :* |
| 01/18/2006 | ELECTRIC - UNDERGROUND | HLEYVA | Approved | IVRS - Inspection :* |
| 01/18/2006 | ELECTRIC - UFER | HLEYVA | Approved | IVRS - Inspection :* |
| 01/18/2006 | BUILDING PRE-SLAB | HLEYVA | Approved | IVRS - Inspection :* |
| 01/18/2006 | EXCAVATION/LAYOUT REBAR & ZON | HLEYVA | Approved | IVRS - Inspection :* |
| 02/14/2006 | ROOF NAILING | CTREVILL | Approved | IVRS - Inspection :* |
| 02/22/2006 | EXT METAL CLIPS/EXT SHEATHING | FSALDIVA | Approved | IVRS - Inspection :* |
| 03/16/2006 | STUCCO MESH | CTREVILL | Approved | IVRS - Inspection :* |
| 03/17/2006 | PLUMBING - GAS PRESSURE TEST | EDURAZO | Approved | IVRS - Inspection :* |
| 03/17/2006 | MECHANICAL - INTERMEDIATE | EDURAZO | Approved | IVRS - Inspection :* |
| 03/17/2006 | PLUMBING - INTERMEDIATE | EDURAZO | Approved | IVRS - Inspection :* |
| 03/17/2006 | ELECTRIC - INTERMEDIATE | EDURAZO | Approved | IVRS - Inspection :* |
| 03/17/2006 | FRAMING | EDURAZO | Approved | IVRS - Inspection :* |
| 03/21/2006 | ELECTRIC - CONSTRUCTION POWER | CTREVILL | Approved | IVRS - Inspection :* |
| 03/21/2006 | ELECTRIC - CABLE DROP | CTREVILL | Approved | IVRS - Inspection :* |
| 03/22/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | |
| 03/22/2006 | ELECTRIC - TEMPORARY SERVICE | CTREVILL | Approved | |
| 04/03/2006 | SHEET ROCK NAILING | CTREVILL | Approved | IVRS - Inspection :* |
| 04/07/2006 | PLUMBING - YARD WTR LINE/TEST | RFREIDIN | Approved | IVRS - Inspection :* |
| 04/07/2006 | PLUMBING - SEWER HCS CONNECT | RFREIDIN | Approved | IVRS - Inspection :* |
| 05/31/2006 | MECHANICAL - FINAL | CTREVILL | Approved | IVRS - Inspection :* |
| 05/31/2006 | PLUMBING - FINAL | CTREVILL | Approved | IVRS - Inspection :* |
| 05/31/2006 | OUTDOOR LIGHTING FINAL | CTREVILL | Approved | IVRS - Inspection :* |
| 05/31/2006 | ELECTRIC - FINAL | CTREVILL | Approved | IVRS - Inspection :* |
| 06/09/2006 | BUILDING - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 06/09/2006 | U VALUE FOR WINDOW | DQUINN | Approved | IVRS - Inspection :* |
| 06/12/2006 | PERMIT FINALED | BFLORES | Approved | |
| 06/12/2006 | BUILDING ABOVE CEILING | CTREVILL | Approved | |
| 06/12/2006 | BUILDING - PROGRESS | CTREVILL | Approved | |
| 06/12/2006 | ELECTRIC - ABOVE CEILING | CTREVILL | Approved | |
| 06/12/2006 | ELECTRIC - OUTDOOR LIGHTING | CTREVILL | Approved | |
| 06/12/2006 | ELECTRIC - TEMP POWER FOR TEST | CTREVILL | Approved | |
| 06/12/2006 | ELECTRIC - PROGRESS | CTREVILL | Approved | |
| 06/12/2006 | PLUMBING - ABOVE CEILING | CTREVILL | Approved | |
| 06/12/2006 | PLUMBING - GAS PRESS TEST FNL | CTREVILL | Approved | |
| 06/12/2006 | PLUMBING - PROGRESS | CTREVILL | Approved | |
| 06/12/2006 | MECHANICAL - ABOVE CEILING | CTREVILL | Approved | |
| 06/12/2006 | MECHANICAL - PROGRESS | CTREVILL | Approved |