Permit: T05CM05790

Parcel: 119421250


Addresses:

4856 S HUELVA LN

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/17/2006 FRAMING Approved IVRS - Inspection :*
03/16/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STAPLES AT UFER (REPEAT)
2) SCREWS AT FHA (REPEAT)
3) FIRE STOP FIRE PLACE
4) FIRE BLOCK AT SGD
5) SECURE WIRES 8" FROM BOX AT ENTRY
6) BLOCK MECH 3 SIDES
7) STOPPED INSPECTION-NOT READY
03/15/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REMOVE STAPLES FROM UFER/DIS-SIMILAR METALS
2) CHANGE SCREWS IN FHA STRAPS TO NAILS
3) BANG PLATE EAST SIDE OF DRYER VENT
4) CREATE 1" CLEARANCE TO B-VENT
5) BLOCK PLENIUM 3 SIDES
6) NEED SOFFIT AT FRESH AIR DUCT
7) BLOCK DUCT BOOTS 3 SIDES
8) CAULK GARAGE LIGHTS, ALL FASCIA-FOAM INTERSECTIONS
9) STOPPED INSPECTION AT GARAGE
03/14/2006 FRAMING Cancelled CANCELLED PER TITO OF HSP
03/13/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER SUPER