Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T05CM05734
Permit Details
Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
1675 S SAN TODARO PL
Address NEW:
1675 S SAN TODARO PL
Apply Date:
11/14/2005
Applicant:
AMERICABUILT CONSTRUCTION INC
Description:
SFR:TD # 16-34-91
Contractors:
- AMERICABUILT CONSTRUCTION INC
Permit Reviews
Permit Number - T05CM05734
Permit Status: C of o
Permit Description: SFR:TD # 16-34-91
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/14/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 11/16/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM05734
Permit Status: C of o
Permit Description: SFR:TD # 16-34-91
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/14/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM05734
Permit Description: SFR:TD # 16-34-91
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/20/2005 | PLUMBING - YARD WTR LINE/TEST | HPEDROZA | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) YARD WATER AND HCS NOT CONNECTED 2) REPLACE SCREW IN DEAD FRONT COVER |
| 12/20/2005 | PLUMBING - SEWER HCS CONNECT | HPEDROZA | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/20/2005 | PLUMBING - ROUGH, SOIL | HPEDROZA | Approved | IVRS - Inspection :* |
| 01/19/2006 | ELECTRIC - UFER | HPEDROZA | Approved | IVRS - Inspection :* |
| 01/19/2006 | BUILDING PRE-SLAB | HPEDROZA | Approved | IVRS - Inspection :* |
| 01/19/2006 | EXCAVATION/LAYOUT REBAR & ZON | HPEDROZA | Approved | IVRS - Inspection :* |
| 02/22/2006 | ROOF NAILING | CTREVILL | Approved | IVRS - Inspection :* |
| 02/22/2006 | EXT METAL CLIPS/EXT SHEATHING | CTREVILL | Approved | IVRS - Inspection :* |
| 03/16/2006 | ELECTRIC - TEMPORARY SERVICE | WNORTH | Approved | IVRS - Inspection :* |
| 03/16/2006 | ELECTRIC - CABLE DROP | WNORTH | Approved | IVRS - Inspection :* |
| 03/17/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED PER W. NORTH |
| 03/23/2006 | MECHANICAL - INTERMEDIATE | CTREVILL | Approved | IVRS - Inspection :* |
| 03/27/2006 | U VALUE FOR WINDOW | CTREVILL | Approved | IVRS - Inspection :* |
| 03/27/2006 | STUCCO MESH | CTREVILL | Approved | IVRS - Inspection :* |
| 03/27/2006 | PLUMBING - INTERMEDIATE | CTREVILL | Approved | IVRS - Inspection :* |
| 03/27/2006 | ELECTRIC - INTERMEDIATE | CTREVILL | Approved | IVRS - Inspection :* |
| 03/27/2006 | FRAMING | CTREVILL | Approved | IVRS - Inspection :* |
| 04/11/2006 | SHEET ROCK NAILING | CTREVILL | Approved | IVRS - Inspection :* |
| 04/11/2006 | SHEET ROCK NAILING | CTREVILL | Approved | CANCELLED PER PAPERWORK TURNED IN BY INSPECTOR C. TREVILLYAN |
| 05/22/2006 | MECHANICAL - FINAL | EDURAZO | Approved | IVRS - Inspection :* |
| 05/22/2006 | PLUMBING - FINAL | EDURAZO | Approved | IVRS - Inspection :* |
| 05/22/2006 | ELECTRIC - FINAL | EDURAZO | Approved | IVRS - Inspection :* |
| 05/22/2006 | BUILDING - FINAL | EDURAZO | Approved | IVRS - Inspection :* |
| 05/23/2006 | PERMIT FINALED | JWEATHER | Approved |