Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/27/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 03/23/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIRE STOP AT KITCHEN VENT 2) FIRE STOP 2ND FLOOR PENETRATIONS 3) SEAL VAPOR BARRIER 4) CONNECT EXHAUST FAN DUCT 5) REPLACE FIRE BLOCK AT STAIRS 6) SUPPORT BOTH ENDS OF FOUR GANG SWITCH BOX AT ENTRY 7) FIRE STOP SUPPLY DUCT-2ND FLOOR CHASE X 2 8) CHECK LIGHT HEIGHT AT STAIRS 6'-8" MINIMUM CLEARANCE TO BOTTOM OF FIXTURE 9) CHECK CLEARANCE OF 3" VENT TO LAUNDRY WINDOW-10' MINIMUM OR 2' ABOVE 10) ITEM 03050 NOT REQUIRED PER PAPERWORK TURNED IN BY INSPECTOR C. TREVILLYAN |
|
| 03/17/2006 | FRAMING | Cancelled | CANCELLED PER SHANE OF AMERICA BUILT | |
| 03/15/2006 | FRAMING | Cancelled | CANCELLED PER SHANE OF AMERICABUILT |