Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY ADDITION
Address:
7974 S LAUDER ST
Address NEW:
7974 S LAUDER ST
Apply Date:
11/14/2005
Applicant:
ARTURO FLORES
Description:
ADDT: AZ RM

Permit Reviews

Permit Number - T05CM05695
Permit Status: Final
Permit Description: ADDT: AZ RM
Start Date Submittal Complete Date Status  
11/14/2005 RESIDENTIAL BLDG/ZONING-WALKTHRU 11/18/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM05695
Permit Status: Final
Permit Description: ADDT: AZ RM
Total Outstanding Activity Conditions - 1
Date Name
11/14/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T05CM05695
Permit Description: ADDT: AZ RM
Total Completed Inspections - 11
Date Description Inspector Results Comments
12/08/2005 BUILDING PRE-SLAB RFREIDIN Approved
12/08/2005 EXCAVATION/LAYOUT REBAR & ZON RFREIDIN Approved IVRS - Inspection :*
01/27/2006 ROOF NAILING RFREIDIN Approved IVRS - Inspection :*
1) VERT TO BE SUPPORTED OVER TRUSS BELOW OR ADD 2 X BLOCKS
2) ADD VERTS TO RIDGE DOWN TO EXISTING FOR SUPPORT
3) SHIM RAFTER TO ROOF AT LONG CUTS, CAP ROOF TO RAFTER
02/14/2006 STEM WALL/RETAINING WALL RFREIDIN Approved IVRS - Inspection :*
1) REAR EXIT STOOP AND REAR WALL TO ADDITION
03/31/2006 FRAMING RFREIDIN Approved IVRS - Inspection :*
1) BLOCK MECH BOOTS 3 SIDES (MIN)
2) AIR ADMITTANCE VALVE BOTH TRAP ARMS
3) BACKING AT GABLE END
4) J-BOXES TO BE EXPOSED
5) CAP OFF CLEANOUT (SEWER GAS)
6) SOLID VERT. SUPPORT INTER POST/BEAM
03/31/2006 STUCCO MESH RFREIDIN Approved IVRS - Inspection :*
03/31/2006 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
04/18/2006 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection :*
09/13/2013 EXT METAL CLIPS/EXT SHEATHING RMORENO Approved PER BLDG FINAL - RMORENO
09/17/2013 ELECTRIC - FINAL RMORENO Approved IVRS - Inspection :*
09/17/2013 BUILDING - FINAL RMORENO Approved IVRS - Inspection :*

Documents

File Name Document Type  
None CONSTRPLANS VIEW
None DOCUMENTS VIEW