Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/13/2013 | EXT METAL CLIPS/EXT SHEATHING | Approved | PER BLDG FINAL - RMORENO | |
| 03/10/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) CAP OFF 2" VENT 2) TWO AIR ADMITTANCE VALVES REQUIRED ON EACH TRAP ARM 3) BLOCK BETWEEN EXISTING TRUSS ENDS 4) NEED FAN BOX 5) PUT VERTS UNDER RAFTER OVER FRAMING 6) IF YOU ARE NOT GOING TO INSTALLE ? B HTR HAVE PLAN CHANGED |
|
| 03/01/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FROM LAST INSPECTION PUT STIFF LEGS UNDER 2 X RAFTERS NOT NAILED TO SIDE 2) CAN LIGHTS NOT INSTALLED 3) NO FAN BOX INSTALLED 4) ELECTRIC PLAN DOESN'T SHOW ALL ITEMS INSTALLED 5) B. BOARD HTR. TO BE ON SEPERATE CIRCUIT. PLEASE ID IT'S LOCATION, WHAT IS THE AMPERAGE 6) OK TO LATH 7) SOLID BLOCK BETWEEN EXISTING TRUSSES AT TOP PLATE 8) PLUMBING NOT SHOWN ON PLAN 2" ABS AND H20 LINES 9) EXTEND 2" ABS THRU ROOF |
|
| 02/01/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) AT OVER FRAMING, VERTICAL LEGS TO BE SUPPORTED BY HORIZONTAL BLOCKS SPANNING ACROSS THE EXISTING TRUSSES, PUT THE BLOCK UNDER THE VERT. NOT NAILED TO THE SIDE 2) OK TO DRY IN ROOF AND WALLS |