Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM05695

Parcel: 141142750


Addresses:

7974 S LAUDER ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
09/13/2013 EXT METAL CLIPS/EXT SHEATHING Approved PER BLDG FINAL - RMORENO
03/10/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) CAP OFF 2" VENT
2) TWO AIR ADMITTANCE VALVES REQUIRED ON EACH TRAP ARM
3) BLOCK BETWEEN EXISTING TRUSS ENDS
4) NEED FAN BOX
5) PUT VERTS UNDER RAFTER OVER FRAMING
6) IF YOU ARE NOT GOING TO INSTALLE ? B HTR HAVE PLAN CHANGED
03/01/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FROM LAST INSPECTION PUT STIFF LEGS UNDER 2 X RAFTERS NOT NAILED TO SIDE
2) CAN LIGHTS NOT INSTALLED
3) NO FAN BOX INSTALLED
4) ELECTRIC PLAN DOESN'T SHOW ALL ITEMS INSTALLED
5) B. BOARD HTR. TO BE ON SEPERATE CIRCUIT. PLEASE ID IT'S LOCATION, WHAT IS THE AMPERAGE
6) OK TO LATH
7) SOLID BLOCK BETWEEN EXISTING TRUSSES AT TOP PLATE
8) PLUMBING NOT SHOWN ON PLAN 2" ABS AND H20 LINES
9) EXTEND 2" ABS THRU ROOF
02/01/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) AT OVER FRAMING, VERTICAL LEGS TO BE SUPPORTED BY HORIZONTAL BLOCKS SPANNING ACROSS THE EXISTING TRUSSES, PUT THE BLOCK UNDER THE VERT. NOT NAILED TO THE SIDE
2) OK TO DRY IN ROOF AND WALLS