Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
11/08/2005
Applicant:
RICHMOND AMERICAN HOMES *C
Description:
SFR:TD#16-41-61
Contractors:
  • RICHMOND AMERICAN HOMES *C

Outstanding Activity Conditions

Permit Number - T05CM05641
Permit Status: C of o
Permit Description: SFR:TD#16-41-61
Total Outstanding Activity Conditions - 1
Date Name
11/08/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T05CM05641
Permit Description: SFR:TD#16-41-61
Total Completed Inspections - 24
Date Description Inspector Results Comments
11/17/2005 PLUMBING - SEWER HCS CONNECT CTREVILL Approved IVRS - Inspection :*
11/17/2005 PLUMBING - ROUGH, SOIL CTREVILL Approved IVRS - Inspection :*
11/29/2005 EXCAVATION/LAYOUT REBAR & ZON CTREVILL Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) WRAP AB'S AND COPPER
11/29/2005 ELECTRIC - UNDERGROUND CTREVILL Approved IVRS - Inspection :*
11/29/2005 ELECTRIC - UFER CTREVILL Approved IVRS - Inspection :*
11/29/2005 BUILDING PRE-SLAB CTREVILL Approved IVRS - Inspection :*
11/29/2005 EXCAVATION/LAYOUT REBAR & ZON CTREVILL Approved IVRS - Inspection :*
12/23/2005 EXT METAL CLIPS/EXT SHEATHING JRIVA Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) CLIP PORCH BEAM TO POST
2) NAIL HOLDOWN TO FULL LENGTH DBL STUDS AND NAIL HOLDOWN STUDS
3) NORTH END OF REAR SOUTH SHEARWALL HOLDOWN NOT ON DBL STUDS-ADD RETRO
4) DIAGONAL BRACES REQUIRE 2-16D NAILS
5) ROOF NOT NAILED TO TRUSSES/FASCIA
6) BLOCK TURNED OSB
12/23/2005 ROOF NAILING JRIVA Approved IVRS - Inspection :
See detailed listing on site.| 999*
01/27/2006 ELECTRIC - TEMPORARY SERVICE RFREIDIN Approved
01/27/2006 ELECTRIC - CABLE DROP RFREIDIN Approved IVRS - Inspection :*
1) PLUG UNUSED K.O. IN BOTTOM OF PANEL
01/30/2006 TEP CLEARANCE - AM JKOZUCH Approved ECO
02/01/2006 MECHANICAL - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
02/01/2006 PLUMBING - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
02/01/2006 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
02/01/2006 FRAMING RFREIDIN Approved IVRS - Inspection :*
02/01/2006 U VALUE FOR WINDOW RFREIDIN Approved IVRS - Inspection :*
02/01/2006 STUCCO MESH RFREIDIN Approved IVRS - Inspection :*
02/13/2006 SHEET ROCK NAILING JRIVA Approved IVRS - Inspection :*
03/27/2006 MECHANICAL - FINAL RFREIDIN Approved IVRS - Inspection :*
03/27/2006 PLUMBING - FINAL RFREIDIN Approved IVRS - Inspection :*
03/27/2006 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection :*
03/27/2006 BUILDING - FINAL RFREIDIN Approved IVRS - Inspection :*
03/28/2006 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW
None CERT OF OCC VIEW