Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM05641

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
01/05/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/23/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CLIP PORCH BEAM TO POST
2) NAIL HOLDOWN TO FULL LENGTH DBL STUDS AND NAIL HOLDOWN STUDS
3) NORTH END OF REAR SOUTH SHEARWALL HOLDOWN NOT ON DBL STUDS-ADD RETRO
4) DIAGONAL BRACES REQUIRE 2-16D NAILS
5) ROOF NOT NAILED TO TRUSSES/FASCIA
6) BLOCK TURNED OSB