Permit: T05CM05393
Permit Details
Status:
Final
Type:
SINGLE FAMILY NEW
Address:
4919 S CELTA VIGO CT
Address NEW:
4919 S CELTA VIGO CT
Apply Date:
10/24/2005
Applicant:
H S P TUCSON INC
Description:
SFR TD # 16-43-48
Contractors:
- H S P TUCSON INC
Permit Reviews
Permit Number - T05CM05393
Permit Status: Final
Permit Description: SFR TD # 16-43-48
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/24/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 10/24/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM05393
Permit Status: Final
Permit Description: SFR TD # 16-43-48
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/24/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05CM05393
Permit Description: SFR TD # 16-43-48
Total Completed Inspections - 28
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/17/2005 | PLUMBING - ROUGH, SOIL | HPEDROZA | Approved | IVRS - Inspection :* |
| 11/28/2005 | ELECTRIC - UNDERGROUND | CTREVILL | Approved | IVRS - Inspection :* |
| 11/28/2005 | ELECTRIC - UFER | CTREVILL | Approved | IVRS - Inspection :* |
| 11/28/2005 | BUILDING PRE-SLAB | CTREVILL | Approved | IVRS - Inspection :* |
| 11/28/2005 | EXCAVATION/LAYOUT REBAR & ZON | CTREVILL | Approved | IVRS - Inspection :* |
| 12/29/2005 | EXT METAL CLIPS/EXT SHEATHING | HPEDROZA | Approved | 1) BRACING NOT PER CALC'S 2) #3 SHEAR MISSING NAILS 3) WIND BRACE MISSING NAIL 4) NAIL PROTECT PLUMBING FROM OUTSIDE 5) COMPLY WITH DETAIL 524 SD 6) PROVIDE DETAIL FOR ENTRY TOWER FRAMING NOT PER PLAN |
| 12/29/2005 | EXT METAL CLIPS/EXT SHEATHING | CTREVILL | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) RAT RUNS NOT INSTALLED 2) SHEAR TRANSFER NOT PER PLAN-3 PLACES 3) PARTITION CHANNELS NOT NAILED PER PLAN 4) SHIM 3 POINT BEARING AT BACK GIRDER |
| 12/29/2005 | ROOF NAILING | CTREVILL | Approved | IVRS - Inspection :* |
| 01/18/2006 | PLUMBING - GAS PRESSURE TEST | HLEYVA | Approved | IVRS - Inspection :* |
| 01/18/2006 | PLUMBING - GAS PRESSURE TEST | HLEYVA | Approved | IVRS - Inspection :* |
| 01/22/2006 | U VALUE FOR WINDOW | CTREVILL | Approved | IVRS - Inspection :* |
| 01/22/2006 | STUCCO MESH | CTREVILL | Approved | IVRS - Inspection :* |
| 01/22/2006 | MECHANICAL - INTERMEDIATE | CTREVILL | Approved | IVRS - Inspection :* |
| 01/22/2006 | PLUMBING - INTERMEDIATE | CTREVILL | Approved | IVRS - Inspection :* |
| 01/22/2006 | ELECTRIC - INTERMEDIATE | CTREVILL | Approved | IVRS - Inspection :* |
| 01/22/2006 | FRAMING | CTREVILL | Approved | IVRS - Inspection :* |
| 02/05/2006 | SHEET ROCK NAILING | CTREVILL | Approved | IVRS - Inspection :* |
| 02/26/2006 | PLUMBING - SEWER HCS CONNECT | CTREVILL | Approved | IVRS - Inspection :* |
| 02/26/2006 | PLUMBING - YARD WTR LINE/TEST | CTREVILL | Approved | IVRS - Inspection :* |
| 03/06/2006 | ELECTRIC - TEMPORARY SERVICE | RFREIDIN | Approved | |
| 03/06/2006 | ELECTRIC - CABLE DROP | RFREIDIN | Approved | IVRS - Inspection :* |
| 03/07/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | OK FOR ECO PER R. FREIDINGER |
| 04/12/2006 | PLUMBING - FINAL | CTREVILL | Approved | IVRS - Inspection :* |
| 04/12/2006 | OUTDOOR LIGHTING FINAL | CTREVILL | Approved | IVRS - Inspection :* |
| 04/13/2006 | MECHANICAL - FINAL | CTREVILL | Approved | IVRS - Inspection :* |
| 04/13/2006 | ELECTRIC - FINAL | CTREVILL | Approved | IVRS - Inspection :* |
| 04/13/2006 | BUILDING - FINAL | CTREVILL | Approved | IVRS - Inspection :* |
| 04/18/2006 | PERMIT FINALED | JWEATHER | Approved |