Permit: T05CM04756
Permit Details
Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address:
1751 S PALO VERDE AV
Address NEW:
1751 S PALO VERDE AV
Apply Date:
09/16/2005
Applicant:
SERRATO CARLOS
Description:
ADDT MASTER BEDRM & BATHRM AND FRONT & REAR PORCH
Permit Reviews
Permit Number - T05CM04756
Permit Status: Expired
Permit Description: ADDT MASTER BEDRM & BATHRM AND FRONT & REAR PORCH
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/16/2005 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 12/13/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM04756
Permit Status: Expired
Permit Description: ADDT MASTER BEDRM & BATHRM AND FRONT & REAR PORCH
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/16/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T05CM04756
Permite Description: ADDT MASTER BEDRM & BATHRM AND FRONT & REAR PORCH
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/23/2008 | BUILDING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PAINT ROOF VENTS ABS AND CONDENSATE LINE 2) COMPLETE ALL MECHANICAL WORK 3) BATH GFCI SOUTH TESTS OPEN GROUND 4) EXTEND PRESSURE RELIEF LINE WATER HEATER 5) COMPLY WITH PREVIOUS NOTES 2, 3, 6 & 7 6) RECALL WHEN ALL TRADES COMPLETED |
| 12/23/2008 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/23/2008 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/23/2008 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
Completed Inspections
Permit Status: Expired
Permit Number: T05CM04756
Permit Description: ADDT MASTER BEDRM & BATHRM AND FRONT & REAR PORCH
Total Completed Inspections - 14
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/16/2005 | PLUMBING - ROUGH, SOIL | FVALENCI | Approved | IVRS - Inspection :* |
| 01/12/2006 | PLUMBING - SEWER HCS CONNECT | EDURAZO | Approved | IVRS - Inspection :* |
| 01/26/2006 | EXCAVATION/LAYOUT REBAR & ZON | FVALENCI | Approved | IVRS - Inspection :* |
| 02/13/2006 | BUILDING PRE-SLAB | FVALENCI | Approved | IVRS - Inspection :* |
| 06/15/2006 | ROOF NAILING | FSALDIVA | Approved | IVRS - Inspection :* |
| 06/15/2006 | EXT METAL CLIPS/EXT SHEATHING | FSALDIVA | Approved | IVRS - Inspection :* |
| 09/27/2006 | MECHANICAL - INTERMEDIATE | LHANLY | Approved | IVRS - Inspection :* |
| 09/27/2006 | PLUMBING - INTERMEDIATE | LHANLY | Approved | IVRS - Inspection :* |
| 09/27/2006 | ELECTRIC - INTERMEDIATE | LHANLY | Approved | IVRS - Inspection :* |
| 09/27/2006 | STUCCO MESH | LHANLY | Approved | IVRS - Inspection :* |
| 10/18/2006 | PLUMBING - GAS PRESSURE TEST | CTREVILL | Approved | IVRS - Inspection :* |
| 10/20/2006 | PLUMBING - GAS PRESS TEST FNL | CTREVILL | Approved | IVRS - Inspection :* |
| 11/02/2006 | FRAMING | CTREVILL | Approved | IVRS - Inspection :* |
| 12/29/2006 | SHEET ROCK NAILING | CTREVILL | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) NO PLAN/PERMIT |