1482 E MELRIDGE ST
Address NEW:
1482 E MELRIDGE ST
Apply Date:
09/15/2005
Applicant:
CASSIE CUFFMAN
Description:
ADDITION: PORCH
Permit Reviews
Permit Number - T05CM04739
Permit Status: Final
Permit Description: ADDITION: PORCH
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/15/2005 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 09/15/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM04739
Permit Status: Final
Permit Description: ADDITION: PORCH
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/15/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05CM04739
Permit Description: ADDITION: PORCH
Total Completed Inspections - 8
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/22/2005 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection :* |
| 09/22/2005 | FRAMING | AMATHIES | Approved | IVRS - Inspection :* |
| 09/22/2005 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection :* |
| 09/22/2005 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection :* |
| 09/22/2005 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection :* |
| 10/28/2005 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection : There is no access to the site.| 920*COULD NOT LOCATE ON MAP CALLED PH# OF APPLICANT LEFT MESSAGE-NO CALL BACK |
| 11/01/2005 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | 1) DISCONNECT FOR HOT TUB NEED TO BE 5' MINIMUM FROM WATER AND IN SITE 2) NEED GFI PROTECTION FOR HOT TUB 3) SECURE FLEX FROM DISCONNECT TO TUB 4) PROVIDE REQUIRED BUSHINGS AT BOXES FOR CONDUIT 5) PROVIDE IN USE TYPE COVERS FOR RECEPTACLES 6) CEILING FAN NOT ALLOWED OVER HOT TUB 7) PROVIDE GFI PROTECTION FOR PORCH LITE |
| 01/26/2006 | PERMIT FINALED | JKOZUCH | Approved |