Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T05CM04739
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/25/2006 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 11/01/2005 | ELECTRIC - INTERMEDIATE | Denied | 1) DISCONNECT FOR HOT TUB NEED TO BE 5' MINIMUM FROM WATER AND IN SITE 2) NEED GFI PROTECTION FOR HOT TUB 3) SECURE FLEX FROM DISCONNECT TO TUB 4) PROVIDE REQUIRED BUSHINGS AT BOXES FOR CONDUIT 5) PROVIDE IN USE TYPE COVERS FOR RECEPTACLES 6) CEILING FAN NOT ALLOWED OVER HOT TUB 7) PROVIDE GFI PROTECTION FOR PORCH LITE |
|
| 10/28/2005 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : There is no access to the site.| 920* |