Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY NEW
Apply Date:
09/08/2005
Applicant:
RICHMOND AMERICAN HOMES *C
Description:
SFR TD#:16-43-00
Contractors:
  • RICHMOND AMERICAN HOMES *C

Outstanding Activity Conditions

Permit Number - T05CM04633
Permit Status: Expired
Permit Description: SFR TD#:16-43-00
Total Outstanding Activity Conditions - 5
Date Name
09/08/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
09/08/2005 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
09/08/2005 SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED.
09/08/2005 SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED.
09/08/2005 SPECIAL INSPECTION IS REQUIRED FOR EPOXY BOLTING PER U.A.C. SECTION 306.

Outstanding Inspections

Permit Status: Expired
Permit Number: T05CM04633
Permite Description: SFR TD#:16-43-00
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
02/23/2006 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) H20 IS OFF ?
2) H20 CONNECTOR TO FLUE NOT SECURED (NO SCREWS)
3) MISSING CAP TO FLUE
02/23/2006 MECHANICAL - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*

Completed Inspections

Permit Status: Expired
Permit Number: T05CM04633
Permit Description: SFR TD#:16-43-00
Total Completed Inspections - 21
Date Description Inspector Results Comments
10/18/2005 PLUMBING - SEWER HCS CONNECT CTREVILL Approved IVRS - Inspection :*
10/18/2005 PLUMBING - YARD WTR LINE/TEST CTREVILL Approved IVRS - Inspection :*
10/18/2005 PLUMBING - ROUGH, SOIL CTREVILL Approved IVRS - Inspection :*
11/07/2005 ELECTRIC - UNDERGROUND CTREVILL Approved IVRS - Inspection :*
11/07/2005 ELECTRIC - UFER CTREVILL Approved IVRS - Inspection :*
11/07/2005 BUILDING PRE-SLAB CTREVILL Approved IVRS - Inspection :*
11/07/2005 EXCAVATION/LAYOUT REBAR & ZON CTREVILL Approved IVRS - Inspection :*
11/29/2005 ROOF NAILING CTREVILL Approved IVRS - Inspection :*
12/14/2005 EXT METAL CLIPS/EXT SHEATHING JRIVA Approved IVRS - Inspection :*
12/15/2005 ELECTRIC - TEMPORARY SERVICE DQUINN Approved
12/15/2005 ELECTRIC - CABLE DROP DQUINN Approved IVRS - Inspection :*
12/30/2005 FRAMING JRIVA Approved IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) TRUSS BRACE CUT/MISSING
2) A/C SECONDARY MUST DRAIN IN A CONSPICOUS LOCATION
3) NO DWV WATER TEST
4) MECH DUCT RESTRICTED AT FRONT BEDROOM
5) NAIL PROTECT PLUMBING
6) PEX WITHIN 12" OF RECESSED LIGHTS
7) SHEAR BLOCK MISSING
8) 5/DT1 NOT COMPLIED WITH
9) STOPPED INSPECTION-TOO MANY ITEMS
12/30/2005 PLUMBING - GAS PRESSURE TEST JRIVA Approved IVRS - Inspection :
Work is not complete enough to inspect.| 950*
12/30/2005 MECHANICAL - INTERMEDIATE JRIVA Approved IVRS - Inspection :
Work is not complete enough to inspect.| 950*
12/30/2005 PLUMBING - INTERMEDIATE JRIVA Approved IVRS - Inspection :
Work is not complete enough to inspect.| 950*
12/30/2005 ELECTRIC - INTERMEDIATE JRIVA Approved IVRS - Inspection :
Work is not complete enough to inspect.| 950*
12/30/2005 U VALUE FOR WINDOW JRIVA Approved IVRS - Inspection :*
12/30/2005 STUCCO MESH JRIVA Approved IVRS - Inspection :*
01/12/2006 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection :*
02/23/2006 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection :*
02/23/2006 BUILDING - FINAL RFREIDIN Approved IVRS - Inspection :*

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW