Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
DUPLEX NEW
Address NEW:
1231 W DELAWARE ST #01
Apply Date:
08/29/2005
Applicant:
ESPINOSA ALEX L PC
Description:
NEW DUPLEX

Permit Reviews

Permit Number - T05CM04481
Permit Status: C of o
Permit Description: NEW DUPLEX
Start Date Submittal Complete Date Status  
08/29/2005 PLANS OK TO SUBMIT - RES 08/29/2005 COMPLETED Review Details
08/29/2005 3RD PARTY REVIEW-RESIDENTIAL 10/10/2005 COMPLETED Review Details
10/10/2005 POST 3RD PARTY REVIEW 10/21/2005 COMPLETED Review Details
10/21/2005 RESUBMITTAL 10/27/2005 COMPLETED Review Details
10/27/2005 RESUBMITTAL 10/27/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM04481
Permit Status: C of o
Permit Description: NEW DUPLEX
Total Outstanding Activity Conditions - 1
Date Name
08/29/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T05CM04481
Permit Description: NEW DUPLEX
Total Completed Inspections - 40
Date Description Inspector Results Comments
11/16/2005 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*ABS DWV UNDER SLAB OK
4" BLDG SEWER TO HCS CONNECTION OK
OK TO COVER ALL AREAS
11/16/2005 SITE - SEWER RMYERS Approved IVRS - Inspection :*
11/16/2005 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection :*
11/18/2005 BUILDING PRE-SLAB AMATHIES Approved IVRS - Inspection :*
11/18/2005 EXCAVATION/LAYOUT REBAR & ZON AMATHIES Approved IVRS - Inspection :*
11/21/2005 ELECTRIC - UFER CCLEMENS Approved IVRS - Inspection :*OK TO COVER ELECTRICAL UFER
12/01/2005 REINFORCED MASONRY PRE-GROUT AMATHIES Approved IVRS - Inspection :*
12/05/2005 ROOF NAILING AMATHIES Approved IVRS - Inspection :*
12/05/2005 EXT METAL CLIPS/EXT SHEATHING AMATHIES Approved IVRS - Inspection :*
12/08/2005 ELECTRIC - ABOVE CEILING CCLEMENS Approved IVRS - Inspection :*OK TO COVER ELECTRICAL IN WALLS AND CEILING
12/08/2005 ELECTRIC - INTERMEDIATE CCLEMENS Approved IVRS - Inspection :*
12/09/2005 FRAMING AQUIROZ Approved IVRS - Inspection :*
12/09/2005 PLUMBING - PROGRESS RMYERS Approved IVRS - Inspection :*STRAP GAS PIPING
STRAP ABS
STRAP PEX
ABS WATER TEST OK
TUBS OK
PEX OK PRESSURE TEST OK
CLOSET FLANGES OK
AT K.S TRAP ARM MAY NOT CHANGE SIZE TRAP AND TRAP ARM TO BE SAME SIZE
TRAP MAY BE ONLY ONE SIZE LARGER THAN TAIL PIECE
12/09/2005 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection :*
12/12/2005 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection :*
12/14/2005 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
12/16/2005 U VALUE FOR WINDOW AQUIROZ Approved IVRS - Inspection :*
12/16/2005 STUCCO MESH AQUIROZ Approved IVRS - Inspection :*
12/19/2005 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :*YARD WATER OK TO COVER
12/19/2005 PLUMBING - ABOVE CEILING RMYERS Approved IVRS - Inspection :*
12/20/2005 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*APPROVED
01/06/2006 ELECTRIC - TEMP POWER FOR TEST CCLEMENS Approved IVRS - Inspection :*
01/06/2006 ELECTRIC - CABLE DROP CCLEMENS Approved IVRS - Inspection :*
01/09/2006 TEP CLEARANCE - AM JKOZUCH Approved ECO
02/15/2006 ELECTRIC - FINAL CCLEMENS Approved 1) NOTE: INSTALL ROOF FLASHINGS PROPERLY
02/15/2006 STEM WALL/RETAINING WALL AQUIROZ Approved
02/15/2006 PERMIT FINALED DROBEY Approved
02/15/2006 MECHANICAL - FINAL CWILLIAM Approved
02/15/2006 MECHANICAL - PROGRESS CWILLIAM Approved
02/15/2006 MECHANICAL - ABOVE CEILING CWILLIAM Approved
02/15/2006 PLUMBING - FINAL RMYERS Approved
02/15/2006 PLUMBING - GAS PRESS TEST FNL RMYERS Approved
02/15/2006 OUTDOOR LIGHTING FINAL CCLEMENS Approved
02/15/2006 ELECTRIC - OUTDOOR LIGHTING CCLEMENS Approved
02/15/2006 ELECTRIC - PROGRESS CCLEMENS Approved
02/15/2006 ELECTRIC - UNDERGROUND CCLEMENS Approved
02/15/2006 ELECTRIC - CONSTRUCTION POWER CCLEMENS Approved
02/15/2006 BUILDING - FINAL AQUIROZ Approved
02/15/2006 BUILDING - PROGRESS AQUIROZ Approved
02/15/2006 BUILDING ABOVE CEILING AQUIROZ Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW