Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T05CM04424
Permit Details
Apply Date:
08/25/2005
Applicant:
D R HORTON HOMES
Description:
TOWNHOUSE:TD#16-31-27
Contractors:
- D R HORTON HOMES
Permit Reviews
Permit Number - T05CM04424
Permit Status: C of o
Permit Description: TOWNHOUSE:TD#16-31-27
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/25/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 08/25/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM04424
Permit Status: C of o
Permit Description: TOWNHOUSE:TD#16-31-27
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
08/25/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM04424
Permit Description: TOWNHOUSE:TD#16-31-27
Total Completed Inspections - 25
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/27/2005 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :* 1) CORRECTION MADE |
10/11/2005 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection :*OK TO PLACE CONCRETE SPECIAL INSPECTION IS REQUIRED FOR ALL POST TENSION SLABS IN CITY OF TUCSON. BUILDING OFFICIAL HAS BEEN NOTIFIED. IN THE FUTURE, BEFORE C.O.T SHOWS UP: HAVE ALL CHAIRING-INCLUDING UPSIDE DOWN CHAIRS AT FARMS IN PLACE. HAVE ALL SWEEPS AROUND PLUMBING BOXES AND PIPES PROPERLY SET UP PER PLANS. MAXIMUN EXPOSED CABLE AT LIVE ENDS TO BE 1" PER PLAN. LIVE ENDS OF CABLE OUTSIDE FORM TO BE FREE. DON'T BURY THEM OR HAVE THEM RUNNING UP SIDES OF TAILINGS |
10/11/2005 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection :* 20' REBAR UFER |
10/11/2005 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection :* |
11/10/2005 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection :* INSIDE PARTY WALL OK |
12/19/2005 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :*YARDWATER OK SEWER OK CONTRACTOR TO INSURE CLEAN FILL AROUND ALL PIPING OK TO COVER |
12/19/2005 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :* |
12/22/2005 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* 30 PSI TEST FROM METER TO STOVE, WATER HEATER, FURNACE -- OK |
12/22/2005 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* WATER TEST WASTE & VENT THRU ROOF & WATER DIST. - OK CLOSET FLANGES - OK |
12/22/2005 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :* |
12/22/2005 | FRAMING | AMATHIES | Approved | IVRS - Inspection :* |
12/22/2005 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection :* |
12/22/2005 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection :* |
12/27/2005 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* |
12/28/2005 | U VALUE FOR WINDOW | LHANLY | Approved | IVRS - Inspection :* |
12/28/2005 | STUCCO MESH | LHANLY | Approved | IVRS - Inspection :* |
02/01/2006 | ELECTRIC - TEMPORARY SERVICE | DSANTACR | Approved | IVRS - Inspection :* |
02/01/2006 | ELECTRIC - CABLE DROP | DSANTACR | Approved | IVRS - Inspection :* |
02/02/2006 | TEP CLEARANCE - AM | JKOZUCH | Approved | TEC |
03/09/2006 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
04/26/2006 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection :* |
04/26/2006 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* |
04/26/2006 | PLUMBING - GAS PRESS TEST FNL | BBENEDON | Approved | IVRS - Inspection :* |
04/26/2006 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* |
04/27/2006 | PERMIT FINALED | BFLORES | Approved |